Lo-Carbon Sentinel Kinetic Horizontal

Manufactured in the UK
Building Regulation ADF compliant
Recognised in SAP PCDB
Energy Savings Trust best practice compliant
Up to 86% heat recovery whilst controlling condensation
Programmable Summer bypass
Digital controller for simple and accurate commissioning
External condensate connection
Plug and play controls; Humidistat, Ventwise, Wireless remote
LS inputs (Light Switch)
Self diagnosis for simplified fault finding
Adjustable delay on/delay off timer
 

Select a product

The Sentinel Kinetic Horizontal Range

A wholehouse heat recovery system with up to 81% heat exchange efficiency. An easily accessible heat recovery cube protected by two removable EU3 filters.

Incorporating two Lo-Carbon Energy Saving EC/DC motors ensures long life (typically over double the life of AC motors) and lowest possible energy use.

Fully insulated construction with built in condensation drain. Specifically designed for new build constructions with a high level of insulation.

The Lo-Carbon Sentinel Kinetic Horizontal meets the latest requirements of the Building Regulations ADF for wholehouse system ventilation: System 4 - Continuous mechanical supply and extract with heat recovery.

The Lo-Carbon Sentinel Kinetic Horizontal models have three fully adjustable speeds and a purge setting (maximum airflow). Supplied with the unit is a digital controller that can be used to pre-set the speeds to any required airflow within the performance range.

Integral Humidity Sensor

The integral humidity sensor ('H' models) increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet-room. The night-time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Acoustically lined - low noise levels from on 20 dB(A) @ 3m.

Multiple control options

Five volt-free pairs of switch terminals for sensor inputs allow boosting from a full range of Vent-Axia controllers - humidistats, PIR, timers.

Two terminals with 0-24V outputs allow 0V to 10V proportional control by sophisticated controllers such as CO2 sensors and proportional humidistats.

The optional Ventwise controller senses temperature rise in a bath/shower hot water supply and/or current in a cooker/hob electrical circuit to activate boost, ensuring additional ventilation when needed. Switch-live for boosting via light switches (220-240V AC) or manual Normal/Boost switches. This connection has the advantage of Delay-On and Delay-Off facility.

Delay-On enables you to prevent the Boost airflow between 0 and 10 minutes after a light switch has been activated.

Delay-Off allows the Boost airflow to continue after a light switch is turned off to ensure effective clearance of humidity. This timer is adjustable between 0 and 25 minutes.

Summer Bypass

An internal damper is activated when the outside temperature is less than the room temperature. The damper opens allowing cooler fresh air to bypass the Heat Recovery Cell and reduce the internal temperature towards the pre-set 'Comfort Temperature'. When the inside air temperature reaches the pre-set 'Comfort Temperature' the bypass damper closes.

Frost Protection

In cold climates there is a possibility of frost building up on the intake side of the heat exchanger. In order to prevent damage, the Kinetic reduces supply flow while maintaining extract flow at temperature down to -20°C.

Supply and install a Sentinel Kinetic Horizontal system Wholehouse heat recovery unit as manufactured by:

Vent-Axia
Fleming Way
Crawley West
Sussex
RH10 9YX




Performance:
m³/h
l/s


Max ventilation rate
191 (270) at 150Pa
53 (75)


N° speed settings
3 (variable between 10% and 100%)
 




(300Z in brackets)

Efficiency: The unit should retain up to 79% of the temperature differential of out going air.

Heat exchanger: should be of a multi plate counter-flow type constructed out of aluminium.

Motor: should be a Lowatt Energy Saving DC with ball bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with an electronic thermal overload protective device.

Fan: The fan impeller should be of a backward curved centrifugal type, dynamically balanced.

Ducting spigots: The unit should provide 125mm ø x 50mm long spigots (200Z) or 150mm ø x 50mm long spigots (300Z)for duct connections. (Can be converted to flat ducting).

Filter: should be synthetic material tested to minimum of EU3.

Condensation: The outlet provided should offer connection within the overall depth of the unit.

Construction: The unit outer case should be constructed of galvanised steel. The heat exchanger access doors should give tool-free access to the filters.

Mounting: Horizontal, slab mounting with access from below..

Mains electrical supply: 230VAC 50Hz.

Complies to the following approvals/directives: CE, LVD, EMC.

PRODUCT SPECIFICATION:

The Lo-Carbon Sentinel Kinetic Horizontal models have 2 fully adjustable speeds and a purge setting - maximum. Supplied with the unit is a digital controller that can be used to pre-set the speeds to any required air-flow within the performance range.

The Sentinel Kinetic Horizontal models designed to be horizontally mounted under a slab, with access for servicing and maintenance from below. When mounted in an unheated area ducting must be insulated. 200 Z models are 200mm deep, including condensate and mounting bracket.
300 Z models are 300mm deep, including condensate and mounting bracket.

Condensate drain is through the 'atmosphere' end of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation.

Electrical and control connections are also made on the outside of the unit.

PERFORMANCE:

 

DIMENSIONS:

Weight: 200Z: 26kg 300Z: 38kg

 
Image of Lo-Carbon Sentinel Kinetic Horizontal 200Z
Lo-Carbon Sentinel Kinetic Horizontal 200Z

High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit.

Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 200ZH
Lo-Carbon Sentinel Kinetic Horizontal 200ZH
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version)
Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 300Z
Lo-Carbon Sentinel Kinetic Horizontal 300Z

High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit.

Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 300ZH
Lo-Carbon Sentinel Kinetic Horizontal 300ZH
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version)
Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 200ZP
Lo-Carbon Sentinel Kinetic Horizontal 200ZP

High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit.

Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 200ZPH
Lo-Carbon Sentinel Kinetic Horizontal 200ZPH
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version).
Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 200ZPM
Lo-Carbon Sentinel Kinetic Horizontal 200ZPM

High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (Vent-Wise version).

Please call 0344 856 0590 for further availability information.
Image of Replacement Filter Pack Sentinel Kinetic Horizontal 200ZP/200ZPH/200ZPM
Replacement Filter Pack Sentinel Kinetic Horizontal 200ZP/200ZPH/200ZPM

Replacement filter (pack of 2) for the Sentinel Kinetic Horizontal 200ZP, 200ZPH and 200ZPM

 

Please call 0344 856 0590 for further availability information.
Image of Replacement Filter Pack Sentinel Kinetic Horizontal 200Z/200ZH
Replacement Filter Pack Sentinel Kinetic Horizontal 200Z/200ZH
Replacement filter (pack of 2) for the Sentinel Kinetic Horizontal 200Z and 200ZH
Please call 0344 856 0590 for further availability information.
Image of Replacement Filter (G3 Two Pack) Sentinel Kinetic 300Z/300ZH
Replacement Filter (G3 Two Pack) Sentinel Kinetic 300Z/300ZH

Replacement filters (pack of 2) G3 for the Sentinel Kinetic Horizontal 300Z and 300ZH

Please call 0344 856 0590 for further availability information.
Image of Replacement Filter (M5 Single Supply) Sentinel Kinetic 200Z/200ZH/200ZMH
Replacement Filter (M5 Single Supply) Sentinel Kinetic 200Z/200ZH/200ZMH

Replacement single M5 Supply Filter for the Sentinel Kinetic 200Z/200ZH/200ZMH

Please call 0344 856 0590 for further availability information.
Image of Replacement Filter (M5 Single Supply) Sentinel Kinetic 300Z/300ZH
Replacement Filter (M5 Single Supply) Sentinel Kinetic 300Z/300ZH

Replacement single M5 Supply Filter for the Sentinel Kinetic Horizontal 300Z and 300ZH

Please call 0344 856 0590 for further availability information.
Image of Wireless enable kit
Wireless enable kit
The Wireless enable kit allows the Kinetic to be set to boost or purge from a remote wireless switch. One switch is supplied with the kit. Up to three additional switches may be linked to the wireless receiver.
Please call 0344 856 0590 for further availability information.
Image of Wireless Transmitter Controller
Wireless Transmitter Controller
• Additional controller for 441865 and 439352 • A maximum of 4 controllers can be used per system • Can be connected to other accessories (eg Humidistat) to send a boost signal wirelessly
Please call 0344 856 0590 for further availability information.
Ventwise Current Sensor 6m
Current sensor for use with Ventwise Controller. 6 metre lead length
Please call 0344 856 0590 for further availability information.
Ventwise Current Sensor 12m
Current sensor for use with Ventwise Controller. 12 metre lead length
Please call 0344 856 0590 for further availability information.
Ventwise Temperature Sensor 12m
Temperature sensor for use with Ventwise Controller. 12 metre lead length
Please call 0344 856 0590 for further availability information.
Ventwise Temperature Sensor 6m
Temperature sensor for use with Ventwise Controller. 6 metre lead length
Please call 0344 856 0590 for further availability information.
Kinetic Vent Wise Controller
The award wining Vent Wise controller has been designed to fully automate a ventilation system. The unit can be used to switch the unit between trickle and boost speed. The controller saves energy by only switching when cooking is taking place or condensation is being generated. The current sensor detects when the power supply to an oven or hob is switched on. The temperature sensor detects the rise in temperature in the hot feed to a bath or shower. A combination of up to three sensors may be used with one controller This controller consists of a small pcb which is plugged onto the control board alongside the terminal connectors. This converts switches 1 to 3 into sensor inputs. A combination of up to three current and/or temperature sensors can then be connected.
Please call 0344 856 0590 for further availability information.

 

Raadpleeg de tab Downloads voor technische informatie

 

 

Overview

The Sentinel Kinetic Horizontal Range

A wholehouse heat recovery system with up to 81% heat exchange efficiency. An easily accessible heat recovery cube protected by two removable EU3 filters.

Incorporating two Lo-Carbon Energy Saving EC/DC motors ensures long life (typically over double the life of AC motors) and lowest possible energy use.

Fully insulated construction with built in condensation drain. Specifically designed for new build constructions with a high level of insulation.

The Lo-Carbon Sentinel Kinetic Horizontal meets the latest requirements of the Building Regulations ADF for wholehouse system ventilation: System 4 - Continuous mechanical supply and extract with heat recovery.

The Lo-Carbon Sentinel Kinetic Horizontal models have three fully adjustable speeds and a purge setting (maximum airflow). Supplied with the unit is a digital controller that can be used to pre-set the speeds to any required airflow within the performance range.

Integral Humidity Sensor

The integral humidity sensor ('H' models) increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet-room. The night-time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Acoustically lined - low noise levels from on 20 dB(A) @ 3m.

Multiple control options

Five volt-free pairs of switch terminals for sensor inputs allow boosting from a full range of Vent-Axia controllers - humidistats, PIR, timers.

Two terminals with 0-24V outputs allow 0V to 10V proportional control by sophisticated controllers such as CO2 sensors and proportional humidistats.

The optional Ventwise controller senses temperature rise in a bath/shower hot water supply and/or current in a cooker/hob electrical circuit to activate boost, ensuring additional ventilation when needed. Switch-live for boosting via light switches (220-240V AC) or manual Normal/Boost switches. This connection has the advantage of Delay-On and Delay-Off facility.

Delay-On enables you to prevent the Boost airflow between 0 and 10 minutes after a light switch has been activated.

Delay-Off allows the Boost airflow to continue after a light switch is turned off to ensure effective clearance of humidity. This timer is adjustable between 0 and 25 minutes.

Summer Bypass

An internal damper is activated when the outside temperature is less than the room temperature. The damper opens allowing cooler fresh air to bypass the Heat Recovery Cell and reduce the internal temperature towards the pre-set 'Comfort Temperature'. When the inside air temperature reaches the pre-set 'Comfort Temperature' the bypass damper closes.

Frost Protection

In cold climates there is a possibility of frost building up on the intake side of the heat exchanger. In order to prevent damage, the Kinetic reduces supply flow while maintaining extract flow at temperature down to -20°C.

Supply and install a Sentinel Kinetic Horizontal system Wholehouse heat recovery unit as manufactured by:

Vent-Axia
Fleming Way
Crawley West
Sussex
RH10 9YX




Performance:
m³/h
l/s


Max ventilation rate
191 (270) at 150Pa
53 (75)


N° speed settings
3 (variable between 10% and 100%)
 




(300Z in brackets)

Efficiency: The unit should retain up to 79% of the temperature differential of out going air.

Heat exchanger: should be of a multi plate counter-flow type constructed out of aluminium.

Motor: should be a Lowatt Energy Saving DC with ball bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with an electronic thermal overload protective device.

Fan: The fan impeller should be of a backward curved centrifugal type, dynamically balanced.

Ducting spigots: The unit should provide 125mm ø x 50mm long spigots (200Z) or 150mm ø x 50mm long spigots (300Z)for duct connections. (Can be converted to flat ducting).

Filter: should be synthetic material tested to minimum of EU3.

Condensation: The outlet provided should offer connection within the overall depth of the unit.

Construction: The unit outer case should be constructed of galvanised steel. The heat exchanger access doors should give tool-free access to the filters.

Mounting: Horizontal, slab mounting with access from below..

Mains electrical supply: 230VAC 50Hz.

Complies to the following approvals/directives: CE, LVD, EMC.

Technical

PRODUCT SPECIFICATION:

The Lo-Carbon Sentinel Kinetic Horizontal models have 2 fully adjustable speeds and a purge setting - maximum. Supplied with the unit is a digital controller that can be used to pre-set the speeds to any required air-flow within the performance range.

The Sentinel Kinetic Horizontal models designed to be horizontally mounted under a slab, with access for servicing and maintenance from below. When mounted in an unheated area ducting must be insulated. 200 Z models are 200mm deep, including condensate and mounting bracket.
300 Z models are 300mm deep, including condensate and mounting bracket.

Condensate drain is through the 'atmosphere' end of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation.

Electrical and control connections are also made on the outside of the unit.

PERFORMANCE:

 

DIMENSIONS:

Weight: 200Z: 26kg 300Z: 38kg

 

Models

Image of Lo-Carbon Sentinel Kinetic Horizontal 200Z
Lo-Carbon Sentinel Kinetic Horizontal 200Z

High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit.

Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 200ZH
Lo-Carbon Sentinel Kinetic Horizontal 200ZH
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version)
Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 300Z
Lo-Carbon Sentinel Kinetic Horizontal 300Z

High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit.

Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 300ZH
Lo-Carbon Sentinel Kinetic Horizontal 300ZH
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version)
Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 200ZP
Lo-Carbon Sentinel Kinetic Horizontal 200ZP

High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit.

Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 200ZPH
Lo-Carbon Sentinel Kinetic Horizontal 200ZPH
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version).
Please call 0344 856 0590 for further availability information.
Image of Lo-Carbon Sentinel Kinetic Horizontal 200ZPM
Lo-Carbon Sentinel Kinetic Horizontal 200ZPM

High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (Vent-Wise version).

Please call 0344 856 0590 for further availability information.

Accessories

Image of Replacement Filter Pack Sentinel Kinetic Horizontal 200ZP/200ZPH/200ZPM
Replacement Filter Pack Sentinel Kinetic Horizontal 200ZP/200ZPH/200ZPM

Replacement filter (pack of 2) for the Sentinel Kinetic Horizontal 200ZP, 200ZPH and 200ZPM

 

Please call 0344 856 0590 for further availability information.
Image of Replacement Filter Pack Sentinel Kinetic Horizontal 200Z/200ZH
Replacement Filter Pack Sentinel Kinetic Horizontal 200Z/200ZH
Replacement filter (pack of 2) for the Sentinel Kinetic Horizontal 200Z and 200ZH
Please call 0344 856 0590 for further availability information.
Image of Replacement Filter (G3 Two Pack) Sentinel Kinetic 300Z/300ZH
Replacement Filter (G3 Two Pack) Sentinel Kinetic 300Z/300ZH

Replacement filters (pack of 2) G3 for the Sentinel Kinetic Horizontal 300Z and 300ZH

Please call 0344 856 0590 for further availability information.
Image of Replacement Filter (M5 Single Supply) Sentinel Kinetic 200Z/200ZH/200ZMH
Replacement Filter (M5 Single Supply) Sentinel Kinetic 200Z/200ZH/200ZMH

Replacement single M5 Supply Filter for the Sentinel Kinetic 200Z/200ZH/200ZMH

Please call 0344 856 0590 for further availability information.
Image of Replacement Filter (M5 Single Supply) Sentinel Kinetic 300Z/300ZH
Replacement Filter (M5 Single Supply) Sentinel Kinetic 300Z/300ZH

Replacement single M5 Supply Filter for the Sentinel Kinetic Horizontal 300Z and 300ZH

Please call 0344 856 0590 for further availability information.
Image of Wireless enable kit
Wireless enable kit
The Wireless enable kit allows the Kinetic to be set to boost or purge from a remote wireless switch. One switch is supplied with the kit. Up to three additional switches may be linked to the wireless receiver.
Please call 0344 856 0590 for further availability information.
Image of Wireless Transmitter Controller
Wireless Transmitter Controller
• Additional controller for 441865 and 439352 • A maximum of 4 controllers can be used per system • Can be connected to other accessories (eg Humidistat) to send a boost signal wirelessly
Please call 0344 856 0590 for further availability information.
Ventwise Current Sensor 6m
Current sensor for use with Ventwise Controller. 6 metre lead length
Please call 0344 856 0590 for further availability information.
Ventwise Current Sensor 12m
Current sensor for use with Ventwise Controller. 12 metre lead length
Please call 0344 856 0590 for further availability information.
Ventwise Temperature Sensor 12m
Temperature sensor for use with Ventwise Controller. 12 metre lead length
Please call 0344 856 0590 for further availability information.
Ventwise Temperature Sensor 6m
Temperature sensor for use with Ventwise Controller. 6 metre lead length
Please call 0344 856 0590 for further availability information.
Kinetic Vent Wise Controller
The award wining Vent Wise controller has been designed to fully automate a ventilation system. The unit can be used to switch the unit between trickle and boost speed. The controller saves energy by only switching when cooking is taking place or condensation is being generated. The current sensor detects when the power supply to an oven or hob is switched on. The temperature sensor detects the rise in temperature in the hot feed to a bath or shower. A combination of up to three sensors may be used with one controller This controller consists of a small pcb which is plugged onto the control board alongside the terminal connectors. This converts switches 1 to 3 into sensor inputs. A combination of up to three current and/or temperature sensors can then be connected.
Please call 0344 856 0590 for further availability information.

Downloads