shadow

VA140/VA150 Range - Axial Kitchen and Utility Room Fans


 kitchen

Overview

VA150 Window and Wall models and VA140 Panel models are designed to alleviate the everyday problems that condensation and household odours may cause. Effectively extracts odours and moisture laden air from kitchen (K) and utility (U) rooms giving a healthy and fresh environment.

Model Range

VA150P WW
VA150 Window and Wall models and VA140 Panel models are designed to alleviate the everyday problems that condensation and household odours may cause. Effectively extracts odours and moisture laden air from kitchen (K) and utility (U) rooms giving a healthy and fresh environment. Shutters The louvred shutter on the VA140 is thermo-electrically operated and is concealed behind the interior grille. Operates automatically when the fan is switched On. Trickle vent facility available on all models.
Stock Ref No: 152110B
VA150A WW
VA150 Window and Wall models and VA140 Panel models are designed to alleviate the everyday problems that condensation and household odours may cause. Effectively extracts odours and moisture laden air from kitchen (K) and utility (U) rooms giving a healthy and fresh environment. Shutters The louvred shutter on the VA140 is thermo-electrically operated and is concealed behind the interior grille. Operates automatically when the fan is switched On. Trickle vent facility available on all models.
Stock Ref No: 153110B
VA140/150KP
VA150 Window and Wall models and VA140 Panel models are designed to alleviate the everyday problems that condensation and household odours may cause. Effectively extracts odours and moisture laden air from kitchen (K) and utility (U) rooms giving a healthy and fresh environment. Shutters The louvred shutter on the VA140 is thermo-electrically operated and is concealed behind the interior grille. Operates automatically when the fan is switched On. Trickle vent facility available on all models.
Stock Ref No: 140120A
VA140/150KT
VA150 Window and Wall models and VA140 Panel models are designed to alleviate the everyday problems that condensation and household odours may cause. Effectively extracts odours and moisture laden air from kitchen (K) and utility (U) rooms giving a healthy and fresh environment. Shutters The louvred shutter on the VA140 is thermo-electrically operated and is concealed behind the interior grille. Operates automatically when the fan is switched On. Trickle vent facility available on all models.
Stock Ref No: 140220B
VA140/150KH
VA150 Window and Wall models and VA140 Panel models are designed to alleviate the everyday problems that condensation and household odours may cause. Effectively extracts odours and moisture laden air from kitchen (K) and utility (U) rooms giving a healthy and fresh environment. Shutters The louvred shutter on the VA140 is thermo-electrically operated and is concealed behind the interior grille. Operates automatically when the fan is switched On. Trickle vent facility available on all models.
Stock Ref No: 140320B
VA140/150KHT
Humidistat controlled kitchen extract fan with adjustable overrun timer (3-25 mins) Humidity adjustment 62-82% RH. Trickle ventilation facility Shutters The louvred shutter on the VA140 is thermo-electrically operated and is concealed behind the interior grille. Operates automatically when the fan is switched On. Trickle vent facility available on all models.
Stock Ref No: 140420B
VA140/150VS
VA150 Window and Wall models and VA140 Panel models are designed to alleviate the everyday problems that condensation and household odours may cause. Effectively extracts odours and moisture laden air from kitchen (K) and utility (U) rooms giving a healthy and fresh environment. Shutters The louvred shutter on the VA140 is thermo-electrically operated and is concealed behind the interior grille. Operates automatically when the fan is switched On. Trickle vent facility available on all models.
Stock Ref No: 458915
[^Top of page]

Product Specification

Shutters
The louvred shutter on the VA140 is thermo-electrically operated and is concealed behind the interior grille. Operates automatically when the fan is switched On. Trickle vent facility available on all models.

Model Range

P models are fitted with an On/Off pullcord which actuates both shutter and fan. Control can be via a remote On/Off switch or through the lighting circuit, as required.

Timer models are fitted with an electronic timer which provides the necessary 15 minute overrun time to comply with Building Regulation requirements for internal kitchens or kitchens that do not have an openable window. Adjustable from 3-25 minutes.

VA140/KH and VA150/KH with built-in humidistat automatically switches the fan ‘On’ and varies the extract rate according to the humidity level. VA140/UH and VA150/UH are a single speed fan with integral humidity control, the controller switches the fan ‘On’ when the Relative Humidity reaches the set point. The fan will continue to run until the RH falls below the set point. Both have integral pullcord switching between automatic humidity control and manual override.

VA140/KHT and VA150/KHT kitchen extract fan with integral humidity sensor, timer and pullcord which combines the functions of a KH and KT.

Building Regulations

The VA140/VA150 Range is specifically sized to meet the Building Regulation requirements for powered extract ventilation in domestic kitchens. All VA140/VA150 models have a Trickle Ventilation Control facility fitted as standard. The VA140/VA150 range is fitted with internal and external louvres conforming to the latest international safety standards.

For areas subject to extreme wind speeds, it is recommended that baffle kits are used. Please contact our Customer Service Department for more details.

Motor

Maintenance free, sealed for life ball bearings in the purpose made electric motor, economical and quiet running. Double insulated appliance.
Supply voltage 220-240V/1/50Hz.


Manufacturers of some fluorescent/low energy lighting systems indicate that these can interfere with other electronic/timing circuits. For reliable operation of these circuits we recommend therefore that a tungsten filament light is used.

Type Stock Ref. No. *Shutter Extract Performance (fid) m³/h l/s Watts dB(A) @ 3m
VA150P WW 152110B PI 220 60 34 37
VA150A WW 153110B I 220 60 34 37
VA140/150KP 140120A PT 245 68 34 36
VA140/150KT 140220A T 245 68 34 36
VA140/150KH 140320A T 85 low 245 boost 24 low 68 boost 34 36
VA140/150KHT 140420A T 85 low 245 boost 24 low 68 boost 34 36
VA140/150VS 458915 PT 100 min 245 max 28 low 68 boost 34 36
*I = instant P = pullcord T = Thermo actuator

[^Top of page]

Performance

Performance



[^Top of page]

Dimensions


Model A B C E F G J K L
VA140 216 224 80 146 60 55 104 152 220 37
VA150 A/P 216 224 130 184 57 37
VA140 Weight 1.75kg, VA150 Weight 2.5kg

Panel Model
Panel fixing hole Ø 152mm
Panel fixing hole Ø 152mm

Wall Model
Wall fixing hole Ø 152mm
Wall fixing hole Ø 152mm

VA150A & VA150P Window Model
Window fixing hole Ø 184mm
Window fixing hole Ø 184mm

[^Top of page]

Typical Specifications

Supply and install a VA140/150 axial fan suitable for mounting in panels, walls or windows with electrically operated backdraught shutter and removable grille as manufactured by

Vent-Axia Ltd
Fleming Way
Crawley
West Sussex
RH10 9YX
Telephone: 0844 856 0590

The fan performance should meet the Building Regulation requirements of 60 litres a second for kitchens and 30 litres a second for utility rooms. It should be double insulated to meet the IEE wiring regulations.

The motor should be manufactured with ball bearings and be fitted with Standard Thermal Overload Protection (S.T.O.P.). The motor should be insulated to Class B.

The fan should be BEAB Approved.

Unique reversible grommet for easy installtion
Integral timer and humidstat
[^Top of page]