T-Series panel/ceiling models are suitable for mounting at any angle in internal partitions, ceilings, ducts and, with louvred grilles, through external walls. When installed only the louvred grille is visible. The range features a unique speed control pack which enables high, medium or low speed to be preset to suit a specific room size or required duty.
T-Series controllers may be used with this model to obtain a choice of speeds, reversible airflow direction and automatic sensor operation. When used with a controller, the speed control pack is removed from the T-Series ventilating unit and fitted into the 3-pin socket in the back of the controller. The Vent-Axia Ecotronic controller gives even greater running economy with its minimum speed setting on 'E' mode and infinitely variable speed control. For this controller the speed control pack remains in the fan.
Easy Cleaning
Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools.
Product Specification
Shutter
With energy saving in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It will operate on both intake and extract and at any angle of mounting.
The shutter is electronically controlled by an actuator with a damped action giving quiet instant operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection.
When the ventilating unit is used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.
TL models do not have a shutter. They are suitable for certain ducted applications, room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off.
Electrical
Suitable for operation in ambient temperatures from -40°C to +50°C.
Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P).
Supply voltage:
220-240V/1/50Hz (120V/1/60 Hz).
| Unit size | | 6 | |
| Type | | TX6PL | TL6PL |
| Stock Ref. No. | | W16 16 10 | W26 16 10 |
| Amps @ 240V | | 0.24 | 0.21 |
| Extract Performance m³/h | Low | 295 | |
| Extract Performance m³/h | Med | 380 | |
| Extract Performance m³/h | High | 435 | |
| Watts (high) | | 45 | 40 |
| dB(A) (med) @ 3m | | 41 | |
| Shutter (TX only) | | Instant | |
| Surface Controllers | T-Series Type TSC | W36 11 19 | |
| Surface Controllers | Ecotronic 130 | W30 01 20 | |
| Surface Controllers | Ecotronic 400 | W36 23 20 | |
| Surface Controllers | Time Switch TTC | W36 13 10 | |
| Unit size | | 7 | |
| Type | | TX7PL | TL7PL |
| Stock Ref. No. | | W16 26 10 | W26 26 10 |
| Amps @ 240V | | 0.24 | 0.21 |
| Extract Performance m³/h | Low | 365 | |
| Extract Performance m³/h | Med | 480 | |
| Extract Performance m³/h | High | 585 | |
| Watts (high) | | 46 | 41 |
| dB(A) (med) @ 3m | | 37 | |
| Shutter (TX only) | | Instant | |
| Surface Controllers | T-Series Type TSC | W36 11 19 | |
| Surface Controllers | Ecotronic 130 | W30 01 20 | |
| Surface Controllers | Ecotronic 400 | W36 23 20 | |
| Surface Controllers | Time Switch TTC | W36 13 10 | |
| Unit size | | 9 | |
| Type | | TX9PL | TL9PL |
| Stock Ref. No. | | W16 36 10 | W26 36 10 |
| Amps @ 240V | | 0.42 | 0.39 |
| Extract Performance m³/h | Low | 565 | |
| Extract Performance m³/h | Med | 830 | |
| Extract Performance m³/h | High | 960 | |
| Watts (high) | | 80 | 75 |
| dB(A) (med) @ 3m | | 43 | |
| Shutter (TX only) | | Instant | |
| Surface Controllers | T-Series Type TSC | W36 11 19 | |
| Surface Controllers | Ecotronic 130 | W30 01 20 | |
| Surface Controllers | Ecotronic 400 | W36 23 20 | |
| Surface Controllers | Time Switch TTC | W36 13 10 | |
| Unit size | | 12 | |
| Type | | TX12PL | TL12PL |
| Stock Ref. No. | | W16 46 10 | W26 46 10 |
| Amps @ 240V | | 0.51 | 0.48 |
| Extract Performance m³/h | Low | 1270 | |
| Extract Performance m³/h | Med | 1640 | |
| Extract Performance m³/h | High | 1885 | |
| Watts (high) | | 105 | 100 |
| dB(A) (med) @ 3m | | 44 | |
| Shutter (TX only) | | Instant | |
| Surface Controllers | T-Series Type TSC | W36 11 19 | |
| Surface Controllers | Ecotronic 130 | W30 01 20 | |
| Surface Controllers | Ecotronic 400 | W36 23 20 | |
| Surface Controllers | Time Switch TTC | W36 13 10 | |
Typical Specifications
Supply and install a T-Series Panel/Ceiling fan as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX Telephone: 01293526062.
The fan should be suitable for installation at any angle in partitions, ceilings and ducts. The unit should flush mounting so that only the louvered grille is visible when installed.
The fan should have a speed control pack which enables high, medium and low speed to be set to suit room size or required duty.
The fan should be fully reversible and be able to be controlled by using variable speed controller or by humidity, air quality or PIR sensors.
The fan should incorporate an electronically controlled instantaneous shutter mechanism that has a facility to be in an open state without the fan running for passive ventilation.
The unit should meet with Document F of the Building Regulations and be BEAB approved.
The motor should be suitable to run at any angle and suitable for operation in ambient temperatures from -40°C to +50°C. and should be fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).
Patented Shutter Actuator System
European Patent Number EP 0177215
Patented Remote Speed Control Circuit
European Patent Number EP 0180311.
[^Top of page]