This ever popular range of extract/intake ventilating units continues to satisfy the most demanding requirements of efficient ventilation. The Standard range unit is supplied without a shutter. The shutter is available as an accessory which can be easily fitted within the unit.
Standard range fans are suitable for most forms of single glazing or can be wall mounted in a Vent-Axia fixing plate. Vent-Axia's patented spigot and ring method of fixing ensures easy installation and weather proof joint. The simple integrated component design makes installation and servicing easy.
Easy Cleaning
Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools
Protective Grilles
Where Standard range units are installed in low positions, finger guards provide extra protection to VDE, DIN 31001.
Product Specification
Motor
Purpose designed enclosed motor. Suitable for running at any angle. Quiet running, enclosed.
Supply voltage 220-240V/1/50 Hz.
Suitable for operation in ambient temperatures from -40° to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.).
Shutter
Type SD/R. This extract/intake shutter fits inside the Vent-Axia unit and closes against unwanted backdraughts. It can be fitted at the same time as the unit or at a later date if required.
Airflow operated for extract use, cord operated lock for intake use. For all models mounted in vertical surfaces.
| Unit size | 6 | 7 | 9 | 12 |
| Type | S6/WW | S7/WW | S9/WW | S12/WW |
| Stock Ref. No. | 13 13 10 | 13 23 10 | 13 33 10 | 13 43 10 |
| Amps @ 240V | 0.16 | 0.16 | 0.24 | 0.36 |
| Extract Perf MAX m³/h | 285 | 425 | 710 | 1560 |
| Watts MAX. | 32 | 34 | 53 | 84 |
| dB(A) (med) @ 3m | 35 | 31 | 39 | 42 |
| Shutter Type SD/R | 23 17 10 | 23 27 10 | 23 37 10 | 23 47 10 |
| Range-master |
| RVS Surface | W30 01 10 | W30 01 10 | W30 01 10 | W30 01 10 |
| Flush Fitting | W30 01 10 | W30 01 10 | W30 01 10 | W30 01 10 |
| + 40 01 44 | + 40 01 44 | + 40 01 44 | + 40 01 44 |
| Time Switch Type TTC | W36 13 10 | W36 13 10 | W36 13 10 | W36 13 10 |
| Multi-unit Type MUC | W36 23 10 | W36 23 10 | W36 23 10 | W36 23 10 |
Typical Specifications
Supply and install a Standard Range Window fan as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX Telephone: 01293 526062.
The fan should be suitable for all forms of single glazing, including wire cast, reeded, leaded lights and fixing plates up to 10mm thick.
The fan should have the option of a backdraught shutter.
The fan should be fully reversible and be able to be controlled by using variable speed controllers or by humidity, air quality or TimeSwitches.
The unit should meet with Document F of the Building Regulations.
The motor should be suitable for mounting at any angle and suitable for operation in ambient temperatures from -40°C to +50°C and should be fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).