Overview
The proven Standard range wall models are designed to fit flush into most double brick walls using the rigid wall liner supplied with the unit. Provision is made within the liner for conduit entry. When installed, only the ivory fascia is visible on the internal wall face. The external weather louvre fits flush to the outside. A shutter is available as an accessory which can be easily fitted within the unit, see below.
On new building work the installation and wiring of the wall liner can be completed prior to the final installation of the unit and controller. Fully shrouded connectors on the fascia automatically connect the wiring to the motor when fitted to the wall liner.
Easy Cleaning
Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools. The fascia, motor impeller assembly unplugs from the wall sleeve. The external weather louvre is removed into the room for cleaning. All plastic components can be washed.
Model Range
|
|
| Standard Range Wall Model S6WL |
Classic Retro-Styled Ventilation
The proven Standard Range Wall models
are designed to fit flush into most double
brick walls using the rigid wall liner
supplied with the unit. Provision is made
within the liner for conduit entry. When
installed, only the ivory fascia is visible on
the internal wall face. The external
weather louvre fits flush to the outside.
A shutter is available as an accessory
which can be easily fitted within the unit,
|
|
|
|
|
|
| Standard Range Wall Model S7WL |
Classic Retro-Styled Ventilation
The proven Standard Range Wall models
are designed to fit flush into most double
brick walls using the rigid wall liner
supplied with the unit. Provision is made
within the liner for conduit entry. When
installed, only the ivory fascia is visible on
the internal wall face. The external
weather louvre fits flush to the outside.
A shutter is available as an accessory
which can be easily fitted within the unit,
|
|
|
|
|
|
| Standard Range Wall Model S9WL |
Classic Retro-Styled Ventilation
The proven Standard Range Wall models
are designed to fit flush into most double
brick walls using the rigid wall liner
supplied with the unit. Provision is made
within the liner for conduit entry. When
installed, only the ivory fascia is visible on
the internal wall face. The external
weather louvre fits flush to the outside.
A shutter is available as an accessory
which can be easily fitted within the unit,
|
|
|
|
|
|
| Standard Range Wall Model S12WL |
Classic Retro-Styled Ventilation
The proven Standard Range Wall models
are designed to fit flush into most double
brick walls using the rigid wall liner
supplied with the unit. Provision is made
within the liner for conduit entry. When
installed, only the ivory fascia is visible on
the internal wall face. The external
weather louvre fits flush to the outside.
A shutter is available as an accessory
which can be easily fitted within the unit,
|
|
|
|
[^Top of page]Accessories
|
|
| Ecotronic Controller |
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
|
|
|
|
|
|
| Ambient Response Humidity Sensor |
The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Can be wired into controller "Auto" mode connections. Night time RH increment setback feature suppresses uisance tripping when the humidity level gradually rises as the temperature falls.
Features & Benefits:
- Ambient operating temp range +5°C to +40°C.
- Changeover relay switch.
|
|
|
|
|
|
| Air Quality Sensor |
Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms.
|
|
|
|
|
|
| Ecotronic Humidity Sensor |
An adjustable set point, solid state On/Off sensor. A pullcord provides manual override, indicated by lamp. Adjustable from 65 to 90%RH. Can be wired into controller "Auto" mode connections. Incorporates changeover switch to select low/high speed.
Features & Benefits:
- Ambient operating temp range 0°C to +40°C.
- BEAB Approved.
- Dimensions: 87 x 87 x 33mm (H x W x D).
- Maximum switching load 1 amp inductive.
- Pullcord override indicated by lamp.
- Setting Range: 65% - 90%RH.
|
|
|
|
[^Top of page]Product Specification
Motor
The motor is purpose-designed. Suitable for running at any angle. Quiet running, enclosed, sealed for life ball bearings.
Supply voltage: 220-240V/1/50Hz.
Suitable for operation in ambient temperatures from -40°C to +40°C.
Fitted with Standard Thermal Overload Protection (S.T.O.P.).
Shutter
Type SD/R. This extract/intake shutter fits inside the Vent-Axia unit and closes against unwanted backdraughts. It can be fitted at the same time as the unit or at a later date if required. Airflow operated for extract use, cord operated lock for intake use.
| Unit size | 6 | 7 | 9 | 12 |
| Type | S6/WL | S7/WL | S9/WL | S12/WL |
| Stock Ref. No. | 13 15 10A | 13 25 10A | 13 35 10A | 13 45 10A |
| Amps @ 240V | 0.16 | 0.16 | 0.24 | 0.36 |
| Extract Perf MAX m³/h | 340 | 544 | 856 | 1767 |
| Watts MAX. | 32 | 34 | 53 | 84 |
| dB(A) (med) @ 3m | 39 | 35 | 43 | 46 |
| Shutter Type SD/R | 23 17 10 | 23 27 10 | 23 37 10 | 23 47 10 |
| Range-master | | | | |
| RVS Surface | W30 01 10 | W30 01 10 | W30 01 10 | W30 01 10 |
| Flush Fitting | W30 01 10 | W30 01 10 | W30 01 10 | W30 01 10 |
| + 40 01 44 | + 40 01 44 | + 40 01 44 | + 40 01 44 |
| Time Switch Type TTC | W36 13 10 | W36 13 10 | W36 13 10 | W36 13 10 |
| Multi-unit Type MUC | W36 23 10 | W36 23 10 | W36 23 10 | W36 23 10 |
[^Top of page]Dimensions
| Impeller dia. | 150mm | 190mm | 230mm | 300mm |
| A | 279 | 279 | 279 | 279 |
| B | 203 | 279 | 279 | 356 |
| C | 279 | 362 | 362 | 448 |
| Fixing hole Square | 235 | 311 | 311 | 400 |
| Weight | 4.1kg | 5.7kg | 6.7kg | 10.1kg |


[^Top of page]Typical Specifications
Supply and install a Standard Range Wall fan as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX Telephone: 01293 526062.
The fan should have a rigid wall liner for maximum wall thickness of 279mm. The unit should have fixed electrical connections within the liner for a first fix in a new build situation.
The plate should have the facility to be fixed on the liner making the electrical connection complete.
The fan should have the option of a backdraught shutter.
The fan should be fully reversible and be able to be controlled by using variable speed controllers or by humidity, air quality or TimeSwitches.
The unit should meet with Document F of the Building Regulations. DEMKO Approved.
The motor should be suitable for mounting at any angle and suitable for operation in ambient temperatures from -40°C to +40°C and should be fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).
[^Top of page]