HR300

Overview
The HR300 unit incorporates 2 specially developed mixed flow fans for low noise and efficiency, with up to 70% heat recovery. Effectively lowering internal relative humidity the HR300 unit controls condensation and eliminates mould growth. Designed for through the wall mounting.
Fresh, pre-warmed air from outside is continually provided to the room with simultaneous extraction of stale moist air and smells. Heat is transferred via a unique plastic heat exchanger from outgoing air to the fresh air supply with no cross contamination, maintaining internal temperatures and providing a fresh environment. The unit is fully controllable for speed using a small dedicated speed controller. Automatic ON/OFF control or switching to boost is easily achieved using sensors/timers e.g. humidistat. For summer operation the heatexchanger can be removed and replaced with a plastic divider board to provide positive cooling to rooms.
Available in three speeds: 75, 210 and 300m³/h. It is ideal for light commercial applications including function rooms, offices and classrooms.
Installation

The HR300 unit requires a 380mm x 280mm hole. Units should be level and square in the wall.The unit should be fitted so that it overhangs by minimum of 50mm on the inside, and a minimum of 70mm on the outside. An extension sleeve is available for walls up to 650mm thick.
Performance
| Extract Performance m³/h |
Supply Performance m³/h |
||||
| Trickle | Medium | Boost | Trickle | Medium | Boost |
| 75 | 210 | 300 | 70 | 190 | 270 |
Power Consumption
| Maximum | 108.0W |
Dimensions
Weight: 11kg

Typical Specifications
Supply and install a HR300 through the wall heat recovery unit as manufactured by:
Vent-Axia Clean Air Systems
Fleming Way
Crawley
West Sussex
RH10 9YX
| Performance: | m³/h | l/s |
| Max ventilation rate | 300.0 | 83.33 |
| Low Supply Rate | 70.0 | 19.44 |
| Low Extract Rate | 75.0 | 20.83 |
| Normal Supply Rate | 190.0 | 52.78 |
| Normal Extract Rate | 210.0 | 58.34 |
| Boost Supply Rate | 270.0 | 75.0 |
| Boost Extract Rate | 300.0 | 83.33 |
| N° speed settings | 3 |
Efficiency: The unit should retain up to 70% of the temperature differential of out going air.
Heat exchanger: Should be of a multi plate cross-flow type constructed out of a polymeric plastic with ultra sonic welded joints.
Motor: Should be a 240V 50Hz A/C with sleeve bearings and greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with a manual reset thermal overload protective device.
Fan: The 2-N° polymeric fan impellers should be of a mixed flow type, dynamically balanced mounted on a fixed stator housing.
Controls: The unit should be operated via a remote 3 Position switch, humidistat or a humidiswitch.
Back Draught Shutter: The unit should have the option back draught shutter operated via a thermal actuator set to close when unit is powered down.
Filter: Should be a washable reticulated foam type coarse filter.
Construction: The unit outer case should be a rigid ABS moulding. The internal/external grille should be a cream coloured ABS moulding.
| Sound Levels: | dB(A) @ 3m |
| Trickle: | 37.0 |
| Medium: | 40.0 |
| Boost: | 44.0 |
Mains electrical supply: 230VAC 50Hz.
Complies to the following approvals/directives: LVD, EMC and CE.