HRE350
 Model Stock Ref No
 HRE350 43 15 91
 HRE350B 43 43 96

Using the Vent-Axia LoWatt range can reduce electrical consumption, thus reducing the overall carbon footprint.

Vent-Axia Lo-Carbon™ - Additional SavingsWhen using heat recovery ventilation, the heating system requirement is reduced thus potentially saving another 500kg of carbon per annum.

Overview
A wholehouse heat recovery system with 95% energy efficiency. An easily accessible heat recovery cube protected by two removable EU3 filters. Two constant velocity LoWatt Energy Saving DC fans ensure long life (typically over double the life of AC motors) and lowest possible energy use. Fully insulated construction with built in condensation drain. Fitted with 150mm spigots. Specifically designed for new build homes with a high level of insulation.

The HRE350 is factory set to 3 speeds - 100, 170 and 300m³/h. On the front of the unit is a digital controller that can be used to set the speeds to any required performance. Offering ‘Close Control’ to prevent over ventilating.

In addition the operating temperature settings can be pre-programmed for automatic operation of the summer bypass.
This applies to the HRE350B model only.

back to top

Installation

HRE350 Installation

The HRE350 must be mounted vertically in a roof space or suitable enclosed cupboard when mounted in a unheated area. Ducting should be insulated.

Performance

HRE350 Performance

back to top

Dimensions (mm)

HRE350 Dimensions

Weight: 31kg

back to top

Controller

HRE350 Controller The HRE350 comes complete with a 3 position switch offering 3 speeds - day, night and boost. Incorporated on the controller is a neon indicator that comes on when either the filter is blocked or every 3 months as an indicator to check the filters.

back to top

Typical Specification
Supply and install a HRE350/HRE350B system Wholehouse heat recovery unit as manufactured by:

Vent-Axia Clean Air Systems
Fleming Way
Crawley
West Sussex
RH10 9YX

Performance: m³/h l/s
Max ventilation rate 300 83
N° speed settings 3  

Efficiency: The unit should retain up to 95% of the temperature differential of out going air.

Heat exchanger: should be of a multi plate counter-flow type constructed out of PETG with ultra sonic welded joints.

Motor: should be a Lowatt Energy Saving DC with ball bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with an electronic thermal overload protective device.

Fan: The fan impeller should be of a forward curved centrifugal type, dynamically balanced.

Controls: The unit should contain an integral driver circuit that provides the unit with a constant airflow volume feature. With provision to connect a remote manual 3 speeds.

Ducting spigots: The unit should provide 150mm ø x 45mm long spigots for all duct connections. The inlet and outlet configuration is fixed. (Can be converted to flat ducting).

Filter: should be synthetic material tested to minimum of EU3.

Condensation: The outlet provided should be located centrally at the bottom of the unit.

Construction: The unit outer case should be constructed of white powder coated sheet metal. The heat exchanger access door should be blue powder coated sheet metal and it should be possible to hand the door opening.

Mounting: Vertical only

Sound Levels: dB(A) @ 1m
Speed 1 33.9
Speed 2 41.4
Speed 3 48.8

Mains electrical supply: 230VAC 50Hz.

Complies to the following approvals/directives: CE, LVD, EMC.

back to top

Vent-Axia Lo-Carbon™
Vent-Axia Lo-Carbon™ - 330kg carbon saving
Information:

»Overview
»Installation
»Performance
»Dimensions
»Maintenance
»Controller
»Typical Specification

Downloads:
PDF availableCatalogue Pages
PDF file - 109kb
16s @ 56Kbps
PDF availableO&M Instructions
PDF file - 1106kb
3m 19s @ 56Kbps
PDF availableVACAS Accessories
PDF file - 469kb
1m 9s @ 56Kbps
 
Features & Benefits:
Asthma Sufferers
Indoor Air Quality
General Ventilation
Condensation Control
Noise Ingress
Air Circulation
Controllability
Climate Control
Heat/Cool Recovery
Energy Efficiency

Up to 95% heat recovery whilst controlling condensation

Optional summer by-pass

Meets new Building Regulations

Easy installation using 150mm diameter duct spigots

Minimal running costs due to LoWatt Energy Saving DC fans

Integrated digital controller for setting various speeds

Washable EU3 filters