Ambient Response Humidity Sensor*
|
Humidity Sensor control is fixed at 72 - 75%RH. Incorporates a night time ‘Set Back’ function so as to avoid nuisance tripping as the humidity level rises when the air cools.
An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation.

|
Features & Benefits

• Pullcord override & neon indicator
• Changeover relayswitch
• Operating range: 30% - 90%RH
• Ambient operating temp 5°C to 40°C
• 24V DC SELV
• Dimensions (mm): 87 x 87 x 33
(H x W x D)
• Will fit single gang box for surface
mounting
|
|
| |
Stock Ref: 43 29 45
|
|
Humidity Sensor*
|
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual
override function if required.
This sensor can be wired for either ON/OFF or Trickle Boost operation.

|
Features & Benefits

• Set Point adjustable
• Maximum switching load 1 amp inductive
• Pullcord override indicator
• Ambient operating temperature 0°C to 40°C
• Dimensions (mm): 87 x 87 x 33
(H x W x D)
• Supply voltage 24V DC SELV
|
|
| |
Stock Ref: 43 29 49
|
|
Vent-Axia ThermoSwitch®
|
Automatically switches on fans on either a rise or fall in air temperature. Can be used for Trickle/ Boost operation on either intake or extract systems.

|
Features & Benefits

• Setting range: +6°C to +30°C
• Two internal range limit/locking rings are
included to allow setting within a limited
temperature range or locking at a fixed
set-point
• Sealed sensing mechanism
• Mounting direct on surface only
• Dimensions: 80 x 104 x 36mm (H x W x D)
• Volt free switch connection to Sentinel
|
|
| |
Stock Ref: 56 35 02B
|
|
Air Quality Sensor (AQS)*
|
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms.
The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases.

|
Features & Benefits

• Ambient operating temp range 0°C to 50°C
• MIN - MAX mode or direct Damper control
• Dimensions: 87 x 157 x 47mm (H x W x D)
• Surface mounted
• 1 - 25 min O/R timer
• Supply voltage 24V DC SELV
|
|
| |
Stock Ref: 43 29 53
|
|
Vent-Axia Visionex PIR*
|
A wall or ceiling person presence detector for use with Sentinel. Can be used in MIN - MAX mode or for direct damper control.

|
Features & Benefits

• Fits any UK single gang mounting box
• Adjustable timer overrun (5-25 minutes)
• Range of detection up to 10 metres
• Designed to meet IP43
• Ambient operating temp range 0°C to 50°C
• Supply voltage 24V DC SELV
|
|
| |
Stock Ref: 43 31 62
|
|
7 Day TimeSwitch
|
For applications where regular switching is required at fixed periods or at different times on different days of the week, eg:offices, shops, pubs and restaurants.
The 7 Day TimeSwitch gives twelve On or Off positions per day and can be set for 7 days. The cycle will repeat until changed. Volt free switch connection to Sentinel.

|
Features & Benefits

• Analogue clock display and integral time
switches for ease of setting
• Manual override
• Removable clear plastic cover protects
timeswitch face
• Time base: 7 days
• Shortest switching time: 2 hours
• Ambient operating temperature range
-20°C to +85°C
• Dimensions: 104 x 74 x 52mm (H x W x D)
• Supply voltage 220-240V/1/50Hz
|
|
| |
Stock Ref: 56 35 15
|
|
Remote Speed Control*
|
Provides infinitely variable Sentinel fan speed control between the 2 set points in Proportional mode. This control does NOT provide an ON/OFF switching facility.
The 7 Day TimeSwitch gives twelve On or Off positions per day and can be set for 7 days. The cycle will repeat until changed. Volt free switch connection to Sentinel.

|
Features & Benefits

• Manual control
• located remotely
• 24V DC SELV
• Ambient operating temp -5°C to +40°C
• Dimensions: 84 x 84 x 30mm (H x W x D)
• Will fit single gang box for surface
mounting
|
|
| |
Stock Ref: 42 63 32
|
|
CO2 Duct Probe*
|
High CO2 levels promote increased fatigue and reduced concentration. Sensor monitors CO2 level in extract ducts from conference areas, offices, theatres etc. With Sentinel in Proportional control mode, air extraction rate tracks the CO2 level to improve indoor air quality.

|
Features & Benefits

• 24V DC SELV
• 0 - 2000ppm CO2 working range
• Auto-calibrating NDIR absorption sensor
• Stable drift compensation
• Adjustable probe length
• MAX. IP Rating 65
|
|
| |
Stock Ref: 43 32 59
|
CO2 + Temp Room Sensor*
|
HVAC temperature and carbon dioxide room sensor for ventilation control of residential areas, office areas and classrooms. Used with Sentinel in Proportional control mode. Sensor will monitor both CO2 and temperature levels between the set points, the air extraction rate following the higher of the 2 outputs.

|
Features & Benefits

• 24V DC SELV
• 0 - 2000ppm CO2 working range
• 0 - 50°C working range
• Auto-calibrating NDIR CO2 absorption
sensor
• Thin film platinum temperature sensor for
high accuracy
• Dimensions: 100 x 84 x 25mm (H x W x D)
|
|
| |
Stock Ref: 43 32 57
|
Remote Fan Status Indicator*
|
This Remote Display unit will indicate the running status and condition of the fan or fans. Can be used in all Sentinel operating modes for fan mounting.

|
Features & Benefits

• 24V DC SELV
• Directly connects into the SCU
• Used for single and twin fan mounting
• Ambient operating temp -5°C to +50°C
• Dimensions:86 x 86 x 28mm (H x W x D)
|
|
| |
Stock Ref: 43 38 16
|
|
PIR Grille*
|
PIR grille is on extract grille with an integral flap damper. Suitable for bathrooms and WC’s. The PIR function fully opens the damper when a person presence is detected. The opening time is fixed at 20 mins. Spigot size is 125mm.

|
Features & Benefits

• 12V AC SELV unit using the main
transformer unit supplied
• Integral PIR person presence sensor
controlling damper
• Auto-humidity control damper response at
all times
• 100° viewing angle
• Temperature range 0 - 50°C
• Size: 158 x 150 x 35mm (H x W x D)
• MAX airflow 70m3/hr @100 Pa
|
|
| |
Stock Ref: 43 41 84
|
|
Dampers*
|
Two types available:
a) MM type - opening shut/MIN to open/MAX
controlled by switches and
b) PC type - opening proportionally when
controlled by sensors.
|
Features & Benefits

• Duct sizes available:
100, 125, 150, 200, 250 and 315
• Industry standard actuators
|
|
| |
Typical ordering designation: DVD size MM or PC
|
|
Power Supply*
|
For those situations where a separate 24V DC SELV supply source is required.

|
Features & Benefits

• 24W output capacity
• See F & W for connection details.
|
|
| |
Stock Ref: 43 31 93
|
* PLEASE NOTE: These sensors/controls are unique to Sentinel and CANNOT be used with any other product.
|  |
|