Vent-Axia storage heaters are simple to install, economical to run and virtually maintenance free. IP20 rated.
Ideal for use in living rooms, hallways and landings. The range and can be installed in bathrooms outside Zone 2, provided that the installation complies with IEE regulations.
Vent-Axia Storage Heaters offer comfortable warmth around the clock taking advantage of low tariff electricity.
Installation is remarkably simple. Vent-Axia Storage Heaters are often an economic alternative for new build or in existing properties, particularly where no other fuel source is available.
Features such as snap-on feet, simple wall fixings and quick assembly mean that new installations or replacement of existing units are completed with minimum disruption. The cable entry is at the back of the unit on the bottom right hand side.
Manual models charge throughout the low-tariff period. Automatic models incorporate an ambient thermostat which optimise the charge to suit room conditions, typically saving 15% of energy costs.
Vent-Axia Storage Heaters are slim, compact and aesthetically pleasing. Their attractive neutral finish blends in with furnishings.
 |
Controls are conveniently positioned on top of the storage heater for ease of use. Once the optimum settings are selected, no further adjustment is necessary.
Then just sit back and enjoy comforting warmth day after day after day.
|
|
|
|
|
|
|
|
| VASH6
| | VASH12
| | VASH18
| | VASH24
|
 | Dimensions and Specification |

|
Model (Manual):
|
VASH 6
|
VASH 12
|
VASH 18
|
VASH 24
|
Stock Ref No:
|
45 53 05
|
45 53 06
|
45 53 07
|
45 53 08
|
Model (Automatic):
| -
| VASH 12A
| VASH 18A
| VASH 24A
|
| Stock Ref No:
| -
| 45 53 09
| 45 53 10
| 45 53 11
|
| Output (kW):
| 0.85
| 1.70
| 2.55
| 3.40
|
| Width (mm):
| 315
| 540
| 765
| 990
|
| Height (mm):
| 730
| 730
| 730
| 730
|
| Depth (mm):
| 150
| 150
| 150
| 150
|
| Weight (kg):
| 43
| 79
| 116
| 152
|
| No of Bricks:
| 4
| 8
| 12
| 16
| | |

220-240V-50Hz. BEAB Approved
Guards
Vent-Axia offer a range of guards to provide protection against contact with the heating surface. These can be used in rooms where the very young or less able are likely to be left unsupervised. Simply position the guard over the heater and fix it to the wall for security.
| Model:
| VASHG 6
| VASHG 12
| VASHG 18
| VASHG 24
|
| Stock Ref No:
| 45 59 14
| 45 59 15
| 45 59 16
| 45 59 17
|
| Width (mm):
| 510
| 740
| 960
| 1180
|
| Height (mm):
| 800
| 800
| 800
| 800
|
| Depth (mm):
| 250
| 250
| 250
| 250
|
 | Storage Heater Size Guide |

|
Floor Area
|
Temp Options
|
Total Length of Outside Wall (m) Heater Outputs given in kW
|
| 1.5
| 2
| 3
| 4
| 5
| 6
| 7
| 8
| 9
| 10
|
|
Up to 3m²:
| Comfort:
| 1.7
| 1.7
| 1.7
| 1.7
| 1.7
| 2.55
|
|
|
|
|
|
Background:
| 1.7
| 1.7
| 1.7
| 1.7
| 1.7
| 1.7
|
|
|
|
|
|
Up to 6m²:
| Comfort:
| 1.7
| 1.7
| 1.7
| 1.7
| 2.55
| 2.55
| 2.55
| 3.4
|
|
|
|
Background:
| 1.7
| 1.7
| 1.7
| 1.7
| 1.7
| 2.55
| 2.55
| 2.55
|
|
|
|
Up to 9m²:
| Comfort:
| 1.7
| 1.7
| 2.55
| 2.55
| 2.55
| 2.55
| 3.4
| 3.4
| 3.4
| 3.4
|
|
Background:
| 1.7
| 1.7
| 1.7
| 2.55
| 2.55
| 2.55
| 2.55
| 2.55
| 3.4
| 3.4
|
|
Up to 12m²:
| Comfort:
| 2.55
| 2.55
| 2.55
| 2.55
| 3.4
| 3.4
| 3.4
| 3.4
| 4.25
| 4.25
|
|
Background:
| 1.7
| 1.7
| 2.55
| 2.55
| 2.55
| 2.55
| 3.4
| 3.4
| 3.4
| 3.4
|
|
Up to 15m²:
| Comfort:
| 2.55
| 2.55
| 2.55
| 3.4
| 3.4
| 3.4
| 3.4
| 4.25
| 4.25
| 4.25
|
|
Background:
| 2.55
| 2.55
| 2.55
| 2.55
| 3.4
| 3.4
| 3.4
| 3.4
| 4.25
| 4.25
|
|
Up to 18m²:
| Comfort:
| 2.55
| 3.4
| 3.4
| 3.4
| 3.4
| 4.25
| 4.25
| 4.25
| 4.25
| 5.1
|
|
Background:
| 2.55
| 2.55
| 3.4
| 3.4
| 3.4
| 3.4
| 4.25
| 4.25
| 4.25
| 4.25
|
|
Up to 21m²:
| Comfort:
| 3.4
| 3.4
| 3.4
| 3.4
| 4.25
| 4.25
| 4.25
| 4.25
| 5.1
| 5.1
|
|
Background:
| 2.55
| 3.4
| 3.4
| 3.4
| 3.4
| 3.4
| 4.25
| 4.25
| 4.25
| 4.25
|
|
Up to 24m²:
| Comfort:
| 3.4
| 3.4
| 4.25
| 4.25
| 4.25
| 4.25
| 5.1
| 5.1
| 5.1
| 5.1
|
|
Background:
| 3.4
| 3.4
| 3.4
| 3.4
| 4.25
| 4.25
| 4.25
| 4.25
| 4.25
| 5.1
|
|
Up to 27m²:
| Comfort:
| 4.25
| 4.25
| 4.25
| 4.25
| 4.25
| 5.1
| 5.1
| 5.1
| 5.1
| 5.95
|
|
Background:
| 3.4
| 3.4
| 3.4
| 4.25
| 4.25
| 4.25
| 4.25
| 4.25
| 5.1
| 5.1
|
|
Up to 30m²:
| Comfort:
| 4.25
| 4.25
| 4.25
| 5.1
| 5.1
| 5.1
| 5.1
| 5.95
| 5.95
| 5.95
|
|
Background:
| 3.4
| 4.25
| 4.25
| 4.25
| 4.25
| 4.25
| 5.1
| 5.1
| 5.1
| 5.1
|
|
Floor Area
|
Temp Options
|
Total Length of Outside Wall (m) Heater Outputs given in kW
|
| 11
| 12
| 13
| 14
| 15
| 16
| 17
| 18
| 19
| 20
|
|
Up to 12m²:
| Comfort:
| 4.25
| 4.25
|
|
|
|
|
|
|
|
|
|
Background:
| 3.4
| 4.25
|
|
|
|
|
|
|
|
|
|
Up to 15m²:
| Comfort:
| 4.25
| 5.1
| 5.1
|
|
|
|
|
|
|
|
|
Background:
| 4.25
| 4.25
| 5.1
|
|
|
|
|
|
|
|
|
Up to 18m²:
| Comfort:
| 5.1
| 5.1
| 5.1
| 5.95
|
|
|
|
|
|
|
|
Background:
| 4.25
| 5.1
| 5.1
| 5.1
|
|
|
|
|
|
|
|
Up to 21m²:
| Comfort:
| 5.1
| 5.1
| 5.95
| 5.95
| 5.95
| 5.95
|
|
|
|
|
|
Background:
| 4.25
| 5.1
| 5.1
| 5.1
| 5.1
| 5.95
|
|
|
|
|
|
Up to 24m²:
| Comfort:
| 5.95
| 5.95
| 5.95
| 5.95
| 6.8
| 6.8
| 6.8
|
|
|
|
|
Background:
| 5.1
| 5.1
| 5.1
| 5.1
| 5.95
| 5.95
| 5.95
|
|
|
|
|
Up to 27m²:
| Comfort:
| 5.95
| 5.95
| 5.95
| 6.8
| 6.8
| 6.8
| 6.8
| 8.5
|
|
|
|
Background:
| 5.1
| 5.1
| 5.95
| 5.95
| 5.95
| 5.95
| 5.95
| 6.8
|
|
|
|
Up to 30m²:
| Comfort:
| 5.95
| 6.8
| 6.8
| 6.8
| 6.8
| 8.5
| 8.5
| 8.5
| 8.5
| 8.5
|
|
Background:
| 5.1
| 5.95
| 5.95
| 5.95
| 5.95
| 6.8
| 6.8
| 6.8
| 6.8
| 6.8
|
This table is a GUIDE TO LOADING IN Kw.
For sizes above 3.4kW more than one storage heater will be required.
|