Vent-Axia - Heating, Ventilation and Air Conditioning
HomeAbout UsWhat's NewOur ProductsFan SelectorBuying ProductsKnowledge CentreContact Us

 Product Search:
 

 
Our Products

  Vent-Axia Lo-Carbon Ventilation Range
 
 Domestic Ventilation Product Range
 Commercial Ventilation Product Range
 Vent-Axia Industrial Product Range
 Roof Units Product Range
 Sentinel Demand Ventilation
 Sentinel Totus Demand Energy Recovery Ventilation
 Heat Recovery & Mechanical Extract Systems
 Commercial Air Curtains
 Smoke Fans Range Guide
 Vent-Axia Air Handling
 Vent-Axia Cooling Range
 Vent-Axia Heating Range
 Hygiene Product Range
 Sensors, Controllers & Accessories

Online Shopping

Catalogue Request

LinX Contractor Range

 Route: Our Products \ Domestic Ventilation Product Range \ VA100 Range - Axial Extract Fans

VA100 Range - Axial Extract Fans
VA100 Range Axial Extract Fans

Suitable for a toilet/WC    Suitable for Bathrooms/Shower rooms    IPX4 Rated

Description
The VA100 range from Vent-Axia is designed for domestic bathrooms and WC's. Available as window, wall or panel mounted models. A range of fans with options of shutter, timer or humidity controlled versions.

The VA100 meets and exceeds the Building Regulation (Document F) requirements of 15 l/s for domestic bathrooms with integral WC's. Designed in a clean white finish. Suitable for ambient temperatures up to +40°C fitted with ball bearing motors. IPX4 Rated.

Models
VA100L - Bathroom extract fan. BEAB Approved.
Stock Ref. No. 25 11 10

VA100LT (Timer) - Bathroom and WC fan with adjustable electronic overrun timer and neon light. BEAB Approved.
Stock Ref. No. 25 12 10

VA100X (Shutter) - Bathroom fan with thermo-electric shutter, pullcord and neon light. BEAB Approved.
Stock Ref. No. 25 13 10

VA100XT (Timer/Shutter) - Bathroom fan with adjustable electronic overrun timer, thermoelectric shutter and neon light. BEAB Approved.
Stock Ref. No. 25 14 10

VA100LH (Humidity) - Bathroom fan with presettable integral auto humidity control, neon running light and pullcord. BEAB Approved. Stock Ref. No. 25 16 10

VA100XH (Shutter/Humidity) - Bathroom fan with presettable integral auto humidity control, thermo-electric shutter, neon running light and pullcord. BEAB Approved.
Stock Ref. No. 25 17 10

VA100XHT (Shutter/Humidity/Timer) - Bathroom fan with presettable integral auto humidity control and adjustable electronic overrun timer, thermo-electric shutter and neon light.
Stock Ref. No. 25 15 10

Product Specification

Type Stock Ref. No.
Panel Model
Window Kit White
Grille
Wall Kit
Brown
Grille
Wall Kit
VA100L 25 11 10 25 41 01 25 41 02 25 41 00
VA100LT 25 12 10 25 41 01 25 41 02 25 41 00
VA100X 25 13 10 25 41 01 25 41 02 25 41 00
VA100XT 25 14 10 25 41 01 25 41 02 25 41 00
VA100LH 25 16 10C 25 41 01 25 41 02 25 41 00
VA100XH 25 17 10C 25 41 01 25 41 02 25 41 00
VA100XHT 25 15 10 25 41 01 25 41 02 25 41 00

Type Stock Ref. No. Extract Performance
(panel model)
Watts dB(A)
@ 3m
Shutter
m³/h l/s
VA100L 25 11 10 90 25 15 32  
VA100LT 25 12 10 90 25 15 32  
VA100X 25 13 10 90 25 20 32 Thermo
VA100XT 25 14 10 90 25 21 32 Thermo
VA100LH 25 16 10C 90 25 16 32  
VA100XH 25 17 10 90 25 21 32 Thermo
VA100XHT 25 15 10 90 25 21 32 Thermo

Timer
VA100 models are fitted with an electronic timer which provides the necessary 15 minute overrun time to comply with Building Regulation (Document F) requirements for internal WC ventilation. Adjustable from 3-20 minutes.

To meet IEE Regulations, timer models should be isolated using a 3 pole isolator.
Stock Ref. No. 56 35 18

VA100 Range - Axial Extract Fans

Performance
Panel Model

VA100 Range

Accessories

Air Replacement Grille Set
Air Replacement Grille Set
Ivory Stock Ref. No. 56 14 01
Brown Stock Ref. No. 56 14 00
Quick fix 100mm Wall Grille
Quick fix 100mm Wall Grille
Ivory Stock Ref. No. 56 35 21
Brown Stock Ref. No. 56 35 41
Quick fix 100mm Airflow Shutter
Quick fix 100mm Airflow Shutter
Ivory Stock Ref. No. 56 35 22
Brown Stock Ref. No. 56 35 42

Dimensions (mm)

  A B C D E F G
mm 155 44 56 98 32 89 200
Transformer 148 87 19 49      
Weight 0.55 kg              

Panel Model
Panel Model
Fixing hole diameter 105mmØ

Window Model
Window Model
Fixing hole diameter 105mmØ

Wall Model
Wall Model
Fixing hole diameter 117mmØ
when wall kit is used.

Manufacturers of some fluorescent/low energy lighting systems indicate that these can interfere with other electronic/timing circuits. For reliable operation of these circuits we recommend therefore that a tungsten filament light is used.

Typical Specification
Supply and install a VA100 mains axial fan suitable for mounting in panels, walls or windows, with thermally operated backdraught shutter (X, XT, XH and XHT models only), removable grille and fan running light as supplied by:

Vent-Axia Ltd
Fleming Way
Crawley
West Sussex
RH10 9YX
Telephone: 01293 526062.

The fan performance should meet the Building Regulation (Document F) requirements of 15 litres a second for bathrooms and 6 l/s for toilets,(15 minute timer overrun model for internal WC’s).

The fan should have a ball bearing motor for installation at any angle. The motor should be insulated to Class B.

The fan should be BEAB approved.

Operation
VA100L - via light switch
VA100X - via light switch
VA100LT - via light switch
with timer
overrun facility
VA100XT - via light switch with
timer overrun
facility
VA100LH - via light switch with
integral humidity
sensor and pullcord
fan override
VA100XH - via light switch with
integral humidity
sensor and pullcord
fan override
VA100HT - via integral humidity
sensor/timer
overrun facility.

Drilled with a core cutter Telescopic wall liner
115mm hole is drilled with a core cutter when using a wall fitting kit. Then the telescopic wall liner is fitted

Vent-Axia
Information:
»Description
»Models
»Product Specification
»Timer
»Performance
»Dimensions
»Typical Specification
Downloads:
PDF availableCatalogue Pages
PDF availableWiring Diagrams
PDF availableO&M Instructions
Features & Benefits:
Designed for the safe use in the spray area of a bathroom or shower and within reach of a person using a bath or shower.
Provides the necessary 15 l/s (54m3/h) to comply with Building Regulation requirements for average domestic bathrooms and WC’s.
With electric shutter.
Fan IPX4 rated.
Window, wall or panel mounting.

FAQs Answered:
Can be installed at any angle.
If ceiling mounted a maximum of 3m rigid ducting should be used with a condensation trap.
The maximum length of 1.5mm2 cable between transformer and fan is 8 metres.
Integral humidistat and timer versions available.
Designed for window, wall or ceiling mounting.
  [ HOME | TOP ]  