The Solo Plus SELV range from Vent-Axia has been specially designed for use in the splash area of a bathroom in either through the wall and ducted applications, suitable for internal bathrooms, WCs and other small rooms. Finished in white, the Solo Plus SELV can be flush or surface mounted, with a 2-position 100mm circular spigot for rear entry or connecting to a vertical ducting system. The powerful centrifugal forward curved impeller allows installations using 100mm ducting in straight runs up to 50m, whilst still achieving 54m3/h as required by Document F of the current building regulations.
The new Solo Plus SELV has an adjustable boost speed which is set at installation variable between 57-100m3/h for boost/override operation to meet Building Regulations thus ensuring
minimum energy usage and low sound levels. All models have an optional third speed for
constant trickle ventilation (25m3/h), selectable at installation. Depending on the model the fan will switch from trickle (if selected) to boost via the pullcord/light switch/humidity sensor/PIR.
Four models are available offering features such as, Pullcord, Timer, Humidistat/Timer or PIR versions. All models can be wall; panel or ceiling mounted and can be connected to either circular, rectangular or Vent-Axias System 25 flat ducting, which has been specially designed for concealed applications that can benefit from its ultra slim 25mm depth.
Cable entry is achieved through a rear entry grommet on the top right hand side of the unit. Enclosure of the electrical components is manufactured from flame retardant grade material.
Supply voltage 220-240V/1/50Hz.

Designed for areas where a fan has to be fitted over or within zone 1 in a room containing a fixed bath or shower according to IEE wiring regulations (BS 7671), the Solo Plus SELV fan can be safely installed within the spray area. The fan is rated IPX7. Control is by mains safety isolating transformer unit with 24V DC SELV output, which is sited away from any source of spray and out of reach of a person using a fixed bath or shower.
Controller Supply voltage 220-240V/1/50Hz.
Output to fan SELV 24V DC.

SOLO PLUS SELV P (Pullcord)
Flush or surface mountable. Control by pullcord or from light/remote switch. Constant trickle option. 2 Speed. Adjustable boost. SELV controller.
Stock Ref. No. 42 74 85
SOLO PLUS SELV T (Timer)
Flush or surface mountable. Control by room light switch or other remote switch. 2 Speed.
Constant trickle option. Adjustable boost. Adjustable timer overrun. Delay on timer. SELV
controller.
Stock Ref. No. 42 74 86
SOLO PLUS SELV HT (Humidistat-timer)
Flush or surface mountable. Humidity controlled auto-variable 2 speed fan. Constant
trickle option. Adjustable boost. Adjustable timer overrun. Delay on timer. Adjustable
humidity sensor. SELV controller.
Stock Ref. No. 42 74 87
SOLO PLUS SELV TM (Timer/PIR)
Flush or surface mountable. Control by integral PIR detector. 2 Speed. Constant trickle option. Adjustable boost. PIR movement sensor. SELV controller.
Stock Ref. No. 42 74 88

| Type:
| Solo Plus SELV P
| Solo Plus SELV T
| Solo Plus SELV HT
| Solo Plus SELV TM
|
| Stock Ref No:
| 42 74 81 | 42 74 82 | 42 74 83 | 42 74 84
|
Extract Perf. (m³/h)
| High:
| 105 | 105 | 105 | 105
|
| Med:
| 57 | 57 | 57 | 57
|
| Low:
| 25 | 25 | 25 | 25
|
| Watts
| High:
| 21 | 21 | 21 | 21
|
| Med:
| 6.5 | 6.5 | 6.5 | 6.5
|
| Low:
| 5.3 | 5.3 | 5.3 | 5.3
|
Sound dB(A) @ 3m
| High:
| 42.8 | 42.8 | 42.8 | 42.8
|
| Trickle:
| 23.7 | 23.7 | 23.7 | 23.7
|
Tested at 240VAC @ 50Hz

The shaded area indicates the variable speed boost range, adjustable at installation.
|
|
| | Flush fitted model
| Surface mounted model
| Washable removable filter
|

Can be installed either as recess or surface mounted as standard. No other accessories
are required.
| A
| B
| C
| D
| EØ
| F
| G
| H
| I
| J
| K
| L
|
| 261 | 221 | 107 | 54.5 | 98 | 64
| 61 | 253 | 208 | 37 | 98 | 70
|
Solo + SELV Weight 3.3kg


Supply and Install a Solo Plus SELV (Safety Extra Low Voltage) Centrifugal fan as supplied
by
Vent-Axia Ltd
Fleming Way
Crawley
West Sussex
RH10 9YX
Telephone: 01293 526062.
The fan should be suitable for flush or surface mounting, for wall, panel and ducted
applications. The fan should have a 100mm spigot with integral backdraught shutter
capable of changing its orientation to receive rear entry or vertical ducting. The fan should be able to offer constant trickle ventilation boosted by various integral sensors.
The transformer should be safety isolating to BS EN 60742. The fan should be rated to
IPX7. The fan performance should meet the Building Regulation (Document F) requirements
of 15 litres a second for bathrooms and 6 l/s for toilets with a 15 minute timer overrun.
The transformer should be installed either surface or recess mounted using the supplied
surface mounting box or a plastic two gang mounting box.
The product should incorporate a 24 volt long life ball bearing motor. The motor should be
insulated to Class B and fitted with Standard Thermal Overload Protection (S.T.O.P.) and
designed to operate on SELV 24V DC.
|