 Route: Our Products \ Domestic Ventilation Product Range \ Duet Range - Run and standby fans

Duet Range - Run and standby fans
Duet Range - Run and standby fans

Suitable for Bathrooms/Shower rooms    Suitable for Bathrooms/Shower rooms    Ideal for use in ducted systems

Description
Duet is a range of run and standby fans designed to provide extraction levels that comply with Building regulations (Document F) for bathrooms and WC's and incorporates a run on timer. All models offer automatic changeover on fan failure.Ultra quiet and particularly suitable for areas where unobtrusive sound levels are essential, Duet is available for surface, recessed or duct mounting. Duet meets the requirement of Health Technical Memorandum 2025, foul extract ventilation systems 2.8. Ideal for new build and refurbishment installations.

Duet features include a backdraught shutter, LED indicators showing the status of the unit, self diagnostic check of controls before the fan will start, run and standby facility, 5-25 minute run on timer and 24 hour auto fan changeover. Suitable for ambient temperatures of up to +40°C, built-in dust filters.

Duet is suitable for use with either 100mm diameter ducting or System 50 PVCu ducting, for installations that need concealed ducting, with a minimal ceiling void of only 90mm required. System 50 also combines the advantages of being non-corrodible and nonreverberant with easy installation.

Motor
The motors are manufactured with long life self aligning sleeve bearings, impedance protected. Insulation is to Class H.

The housing and fan scroll are manufactured from high quality polymeric materials. The control circuitry is mounted within its own enclosure.

Built In Controls
Adjustable Timer from 5-25 minutes, to comply with Building Regulations , Document F. 24 hour automatic duty share changeover. Any external electro-mechanical switch can be used eg. ThermoSwitch, HumidiSwitch. Double insulated appliance.
Supply voltage 220-240V/1/50Hz

Controller
Optional Remote indicator
The remote fan indicator unit provides fan status information at a convenient position remote from the main unit. Stock Ref. No.18 00 10C

Models
Duet Surface
Requires 100mm circular hole in wall. Fan 1/ Fan 2 running indicators, fault indicator.
Stock Ref. No.18 05 10C

Duet Recessed
Flush-mounted model with 100mm discharge spigot. Two flush-mounted washable filter panels, Fan 1/Fan 2 running indicators, fault indicator.
Stock Ref. No. 18 06 10C

Duet Duct
Sheet metal construction. Up to 2 inlets can be connected. 100mm discharge spigots. A remote indicator is included with this model.
Stock Ref No. 18 07 10C

Remote Indicator
The remote fan indicator unit provides fan status information at a convenient position remote from the main unit.
Stock Ref. No. 18 00 10C

Wall Fitting Kit
For use with Duet range. Hole size 115mm.
Stock Ref. No. 25 41 02 - White 25 41 00 - Brown

Duet Controller

Product Specification

Type Stock Ref. No. Remote Indicator
Stock Ref. No.
Amps @ 240V Extract Performance Max Watts dB(A) 85m³/h
m³/h l/s
Surface 18 00 10C + 18 00 10C 0.25 122 33 35 Both fans running 37
One fan running 34
Recessed 18 06 10C + 18 00 10C 0.25 122 33 35 Both fans running 36
One fan running 33
Duct 18 07 10C + 18 00 10C 0.25 122 33 35 Both fans running 36
One fan running 33

Single fan only performance

Manufacturers of some fluorescent/low energy lighting systems indicate that these can interfere with other electronic/timing circuits. For reliable operation of these circuits we recommend therefore that a tungsten filament light is used.

Accessories
Wall fitting kit
Wall fitting kit
White Stock Ref. No. 25 41 02
Brown Stock Ref. No. 25 41 00
Air replacement grille set
Air replacement grille set
Ivory Stock Ref. No. 56 14 01
Brown Stock Ref. No. 56 14 00
Quck fix 100mm wall grille
Quck fix 100mm wall grille
White Stock Ref. No. 56 35 21
Brown Stock Ref. No. 56 35 41
Vent-cowl for connection to 100mm rigid pipe
Vent-cowl for connection to 100mm rigid pipe
Stock Ref. No. 56 14 03
100mm Flexible ducting
100mm Flexible ducting
Stock Ref. No. 56 36 04 (3 metre)
Stock Ref. No. 56 66 04 (6 metre)
Condensation trap
Condensation trap
Condensation trap for 100mm rigid duct
Stock Ref. No. 56 35 16

System 50 Duct Components
For full details of system 50 components see the System 50 page.

Dimensions

  A B C D F G
Surface 347 170 224 69 99 35  
Recessed 385 233 366 255 98 230 35
Duct 366 233 230 36 98    

Duet Surface
Duet Surface

Duet Recessed
Duet Recessed

Duet Duct
Duet Duct

Performance

Duet Performance

Typical Specification
Supply and install a Duet run and standby fan suitable for mounting in wall, ceiling or ducted applications as manufactured by

Vent-Axia Ltd
Fleming Way
Crawley
West Sussex
RH10 9YX
Telephone: 01293 526062.

The fan performance should meet building regulations of 30 l/s suitable for bathrooms or utility rooms.

Vent-Axia
Information:
»Description
»Motor
»Built-in Controls
»Controller
»Models
»Product Specification
»Accessories
»System 50 Duct Components
»Dimensions
»Performance
»Typical Specification

Downloads:
PDF availableCatalogue Pages
PDF availableWiring Diagrams
PDF availableO&M Instructions
Features & Benefits:
Designed to meet Local Authority run and standby specifications.
Quiet operation.
Complies with Building Regulation (Document F) requirements.
Now with boost running facility.
Run and standby facility.
Self diagnostic check of controls.
Overrun timer as standard, remote PIR’s or humidistat can be installed.
FAQs Answered:
Can be ceiling mounted.
Can be used with System 50 flat duct.
Duty sharing fans, automatic changeover.
Built-in or remote LED indicator for fan running and fan failure.
  [ HOME | TOP ]  