Vent-Axia - Heating, Ventilation and Air Conditioning
HomeAbout UsWhat's NewOur ProductsFan SelectorBuying ProductsKnowledge CentreContact Us

 Product Search:
 

 
Our Products

  Vent-Axia Lo-Carbon Ventilation Range
 
 Domestic Ventilation Product Range
 Commercial Ventilation Product Range
 Vent-Axia Industrial Product Range
 Roof Units Product Range
 Sentinel Demand Ventilation
 Sentinel Totus Demand Energy Recovery Ventilation
 Heat Recovery & Mechanical Extract Systems
 Commercial Air Curtains
 Smoke Fans Range Guide
 Vent-Axia Air Handling
 Vent-Axia Cooling Range
 Vent-Axia Heating Range
 Hygiene Product Range
 Sensors, Controllers & Accessories

Online Shopping

Catalogue Request

LinX Contractor Range

 Route: Our Products \ Commercial Ventilation Product Range \ T-Series Roof Models

Vent-Axia T-Series Roof Models
T-Series Roof Model
suitable for commercial applicationssuitable for health & leisure facilitiesideal for use in ducted systems


 Descriptionhspace=Description

Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy with T-Series roof models and ventilation accessories. With a low profile cowl, the T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. All four sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.

T-SeriesT-Series features a unique speed control pack which enables high, medium or low speed to be preset to suit room size or required duty. When used with a T-Series TSC controller, the speed control pack is removed from the T-Series ventilating unit and fitted into the 3-pin socket in the back of the controller. The Vent-Axia Ecotronic controller gives even greater running economy with its minimum speed setting and 'E' mode. When using the Ecotronic controller the speed control pack remains in the fan.

back to top

 Shutterhspace=Shutter

With energy saving in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It will operate on both intake and extract and at any angle of mounting.

The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection.

When the ventilating unit is used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.

TL models do not have a shutter. They are suitable for systems where no shutter is required or in a ducted system where the shutter is located elsewhere.

back to top

 Electricalhspace=Electrical

Motor purpose-designed. Suitable for running at any angle. Quiet running, enclosed. Suitable for operation in ambient temperatures from -40°C to +50°C.

Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.). Supply voltage 220-240V/1/50 Hz (120V/1/60 Hz).

back to top

 Easy Cleaninghspace=Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools.

back to top

 Controllers and Sensorshspace=Controllers and Sensors

T-Series Controller T-Series Controller
  • Three speeds. Choice of extract/intake
  • Shutter open, fan Off setting
  • Sensor mode. Enables external electro mechanical switches, eg: Ecotronic, HumidiSwitch, ThermoSwitch and TimeSwitch to control the fan.

T-Series Controller Ecotronic 130 Controller
All the features of T-Series:-
  • Infinitely variable speed control
  • 'E' position for energy saving
  • Minimum speed adjustment.

T-Series Controller Ecotronic 400 Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.

 

T-Series Controller Ambient Response Humidity Sensor
Self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature.Night time RH increment setback feature.

T-Series Controller Air quality sensor
Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas.

T-Series Controller Ecotronic Humidity Sensor
The Ecotronic Humidity Sensor is an adjustable set point, solid state controller. A pullcord provides manual override, indicated by lamp. Adjustable from 65% to 90%RH. Ecotronic includes a relay and can be used with T-Series controller sensor mode.

back to top

 Performancehspace=Performance

Output is for the extract airflow on HIGH.

T-Series Roof model performance

back to top

 Dimensions (mm)hspace=Dimensions (mm)

T-Series Roof Model - Dimensions
 Size 6 (150mm) 7 (190mm) 9 (230mm) 12 (300mm)
 A 100 136 136 171
 B 130 130 150 177
 C 226 265 304 381
 D 220 258 302 378
 E 54 54 54 54
 F 285 400 400 500
 Fixing hole dia. 184 222 260 337
 Weight (kg) 3.96 4.89 6.22 9.28

back to top

 Technical Datahspace=Technical Data

 Unit size 6
 Type TX6RF TL6RF
 Stock Ref. No. W16 12 10 W26 12 10
 Amps @ 240V 0.24 0.21
 Extract
 Performance
 m³/h
Low 195
Med 250
High 290
 Watts (high) 45 40
 dB(A) (med) @ 3m 41
 Shutter (TX only) Instant
 Surface Controllers T-Series Type TSC W36 11 19
Ecotronic 130 W30 01 20
Ecotronic 400 W36 23 20
Time Switch TTC W36 13 10

 Unit size 7
 Type TX7RF TL7RF
 Stock Ref. No. W16 22 10 W26 22 10
 Amps @ 240V 0.24 0.21
 Extract
 Performance
 m³/h
Low 305
Med 395
High 485
 Watts (high) 45 40
 dB(A) (med) @ 3m 37
 Shutter (TX only) Instant
 Surface Controllers T-Series Type TSC W36 11 19
Ecotronic 130 W30 01 20
Ecotronic 400 W36 23 20
Time Switch TTC W36 13 10

 Unit size 9
 Type TX9RF TL9RF
 Stock Ref. No. W16 32 10 W26 32 10
 Amps @ 240V 0.42 0.39
 Extract
 Performance
 m³/h
Low 465
Med 685
High 795
 Watts (high) 80 75
 dB(A) (med) @ 3m 43
 Shutter (TX only) Instant
 Surface Controllers T-Series Type TSC W36 11 19
Ecotronic 130 W30 01 20
Ecotronic 400 W36 23 20
Time Switch TTC W36 13 10

 Unit size 12
 Type TX12RF TL12RF
 Stock Ref. No. W16 42 10 W26 42 10
 Amps @ 240V 0.51 0.48
 Extract
 Performance
 m³/h
Low 1010
Med 1305
High 1485
 Watts (high) 105 100
 dB(A) (med) @ 3m 47
 Shutter (TX only) Instant
 Surface Controllers T-Series Type TSC W36 11 19
Ecotronic 130 W30 01 20
Ecotronic 400 W36 23 20
Time Switch TTC W36 13 10

Flush box Stock Ref. No. 40 01 44

back to top

 Typical Specificationhspace=Typical Specification

Supply and install a T-Series roof fan as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone 01293 526062.

The fan should be suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical glass in exposed areas, and suitable for any types of glass up to 32mm thick. The unit should have the options of fixing rod sets for greater thickness.

The fan should have a speed control pack which enables high, medium and low speed to be set to suit room size or required duty.

The fan should be fully reversible and be able to be controlled by using variable speed controller or by humidity, air quality or PIR sensors.

The fan should incorporate an electronically controlled instantaneous shutter mechanism that has a facility to be in an open state without the fan running for passive ventilation.

The unit should meet with Document F of the Building Regulations and be BEAB approved.

The motor should be suitable to run at any angle and suitable for operation in ambient temperatures from -40°C to +50°C. and should be fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).

Patented Shutter Actuator System
European Patent Number EP 0177215

Patented Remote Speed Control Circuit
European Patent Number EP 0180311.

back to top

Vent-Axia
Information:
»Description
»Performance
»Dimensions
»Typical Specification

Downloads:
PDF availableCatalogue Pages
PDF availableWiring Diagrams
PDF availableO&M Instructions

At a Glance:
Patented electronic shutter system ensures quiet trouble free operation.
Designed to comply with International safety standards.
For the very best from your fan use the Ecotronic controller.
T-Series controllers and sensor save energy by only switching on the units when you want them to, either manually or automatically.

FAQs Answered:
All models can be used for extract and intake.
Suitable for glazing or using roof plates.
Can be connected directly to Vent-Axia ductwork using a direct mount spigot.
A range of compatible soaker flanges is available.
On non glass installations suitable sealing compound should be used.