Vent-Axia - Heating, Ventilation and Air Conditioning
HomeAbout UsWhat's NewOur ProductsFan SelectorBuying ProductsKnowledge CentreContact Us

 Product Search:
 

 
Our Products

  Vent-Axia Lo-Carbon Ventilation Range
 
 Domestic Ventilation Product Range
 Commercial Ventilation Product Range
 Vent-Axia Industrial Product Range
 Roof Units Product Range
 Sentinel Demand Ventilation
 Sentinel Totus Demand Energy Recovery Ventilation
 Heat Recovery & Mechanical Extract Systems
 Commercial Air Curtains
 Smoke Fans Range Guide
 Vent-Axia Air Handling
 Vent-Axia Cooling Range
 Vent-Axia Heating Range
 Hygiene Product Range
 Sensors, Controllers & Accessories

Online Shopping

Catalogue Request

LinX Contractor Range

 Route: Our Products \ Commercial Ventilation Product Range \ T-Series Darkroom Models

Vent-Axia T-Series Darkroom Models
T-Series Darkroom Model
suitable for commercial applications


 Descriptionhspace=Description

A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable.

The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office.

back to top

 Shutterhspace=Shutter

With energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting.

The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection.

When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.

TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C.

back to top

 Electricalhspace=Electrical

Suitable for running at any angle. Quiet running, enclosed. Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).

Supply voltage: 220-240V/1/50Hz (120V/1/60 Hz).

back to top

 Controllers and Sensorshspace=Controllers and Sensors

T-Series Controller T-Series Controller
  • Three speeds. Choice of extract/intake
  • Shutter open, fan Off setting
  • Sensor mode. Enables external electro mechanical switches, eg: Ecotronic, HumidiSwitch, ThermoSwitch and TimeSwitch to control the fan.

T-Series Controller Ecotronic 130 Controller
All the features of T-Series:-
  • Infinitely variable speed control
  • 'E' position for energy saving
  • Minimum speed adjustment.

T-Series Controller Ecotronic 400 Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.

 

T-Series Controller Ambient Response Humidity Sensor
Self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature.Night time RH increment setback feature.

T-Series Controller Air quality sensor
Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas.

T-Series Controller Ecotronic Humidity Sensor
The Ecotronic Humidity Sensor is an adjustable set point, solid state controller. A pullcord provides manual override, indicated by lamp. Adjustable from 65% to 90%RH. Ecotronic includes a relay and can be used with T-Series controller sensor mode.

Click here for full details of controllers and sensors

back to top

 Performancehspace=Performance

Output is for the extract airflow on HIGH.

T-Series Darkroom performance

back to top

 Dimensions (mm)hspace=Dimensions (mm)

T-Series Darkroom Model - Dimensions
 Size 6 (150mm) 7 (190mm) 9 (230mm) 12 (300mm)
 A 100 136 136 171
 B 196 206 229 308
 C 285 400 400 500
 D 220 258 302 378
 E 226 265 304 381
 F 19 19 19 19
 Fixing Hole Diameter 184 222 260 337
 Weight (kg) 4.13 5.33 6.60 10.05

back to top

 Technical Datahspace=Technical Data

 Unit size 6
 Type TX6DR TL6DR
 Stock Ref. No. W16 12 10 W26 12 10
 Amps @ 240V 0.24 0.21
 Extract
 Performance
 m³/h
Low 200
Med 240
High 265
 Watts (high) 45 40
 dB(A) (med) @ 3m 43
 Shutter (TX only) Instant
 Surface Controllers T-Series Type TSC W36 11 19
Ecotronic 130 W30 01 20
Ecotronic 400 W36 23 20
Time Switch TTC W36 13 10

 Unit size 7
 Type TX7DR TL7DR
 Stock Ref. No. W16 22 10 W26 22 10
 Amps @ 240V 0.24 0.21
 Extract
 Performance
 m³/h
Low 330
Med 415
High 530
 Watts (high) 46 41
 dB(A) (med) @ 3m 2
 Shutter (TX only) Instant
 Surface Controllers T-Series Type TSC W36 11 19
Ecotronic 130 W30 01 20
Ecotronic 400 W36 23 20
Time Switch TTC W36 13 10

 Unit size 9
 Type TX9DR TL9DR
 Stock Ref. No. W16 32 10 W26 32 10
 Amps @ 240V 0.42 0.39
 Extract
 Performance
 m³/h
Low 455
Med 630
High 725
 Watts (high) 80 75
 dB(A) (med) @ 3m 42
 Shutter (TX only) Instant
 Surface Controllers T-Series Type TSC W36 11 19
Ecotronic 130 W30 01 20
Ecotronic 400 W36 23 20
Time Switch TTC W36 13 10

 Unit size 12
 Type TX12DR TL12DR
 Stock Ref. No. W16 42 10 W26 42 10
 Amps @ 240V 0.51 0.48
 Extract
 Performance
 m³/h
Low 870
Med 1040
High 1130
 Watts (high) 105 100
 dB(A) (med) @ 3m 42
 Shutter (TX only) Instant
 Surface Controllers T-Series Type TSC W36 11 19
Ecotronic 130 W30 01 20
Ecotronic 400 W36 23 20
Time Switch TTC W36 13 10

Flush box Stock Ref. No. 40 01 44

back to top

 Typical Specificationhspace=Typical Specification

Supply and install a T-Series Darkroom fan as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX Telephone: 01293526062.

The fan should be able to give a minimum of 10 air changes per hour, it should have two cowls to give light protection while mounted in windows partitions, external walls and roofs. The fan should be able to extract through walls up to 370mm thick by use of extended fixing rods.

The fan should have a speed control pack which enables high, medium and low speed to be set to suit room size or required duty.

The fan should be fully reversible and be able to be controlled by using variable speed controllers or by humidity, air quality or PIR sensors.

The fan should incorporate an electronically controlled instantaneous shutter mechanism that has a facility to be in an open state without the fan running for passive ventilation.

The unit should meet with Document F of the Building Regulations and be BEAB approved.

The motor should be suitable to run at any angle and suitable for operation in ambient temperatures from -40°C to +50°C and should be fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).

Patented Shutter Actuator System
European Patent Number EP 0177215

Patented Remote Speed Control Circuit
European Patent Number EP 0180311.

back to top

Vent-Axia
Information:
»Description
»Performance
»Dimensions
»Typical Specification

Downloads:
PDF availableCatalogue Pages
PDF availableWiring Diagrams

At a Glance:
Extract/intake models in 4 sizes: Size 6, 7, 9 and 12.
Specially designed to provide extract/intake ventilation in darkrooms, X-ray areas, etc.
Patented electronic shutter system ensures quiet trouble free operation.
For the very best from your fan use the Ecotronic controller.
Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools.

FAQs Answered:
Suitable for panel, wall or roof applications
All models can be used for extract or intake
Suitable for most darkroom applications, but for total light exclusion contact your local Vent-Axia office
T-Series controllers require 5 core cable
Use pairs of black non-vision grilles for air replacement
  [ HOME | TOP ]  
 © Copyright 2007, Vent-Axia Ltd