Vent-Axia - Heating, Ventilation and Air Conditioning
HomeAbout UsWhat's NewOur ProductsFan SelectorBuying ProductsKnowledge CentreContact Us

 Product Search:
 

 
Our Products

  Vent-Axia Lo-Carbon Ventilation Range
 
 Domestic Ventilation Product Range
 Commercial Ventilation Product Range
 Vent-Axia Industrial Product Range
 Roof Units Product Range
 Sentinel Demand Ventilation
 Sentinel Totus Demand Energy Recovery Ventilation
 Heat Recovery & Mechanical Extract Systems
 Commercial Air Curtains
 Smoke Fans Range Guide
 Vent-Axia Air Handling
 Vent-Axia Cooling Range
 Vent-Axia Heating Range
 Hygiene Product Range
 Sensors, Controllers & Accessories

Online Shopping

Catalogue Request

LinX Contractor Range

 Route: Our Products \ Commercial Ventilation Product Range \ Standard Range - Wall Model

Standard Range - Wall Model
Standard Range - Wall Model
suitable for commercial applicationssuitable for health & leisure facilitiesIPX4 rated


 hspace=

Description

The proven Standard range wall models are designed to fit flush into most double brick walls using the rigid wall liner supplied with the unit. Provision is made within the liner for conduit entry. When installed, only the ivory fascia is visible on the internal wall face. The external weather louvre fits flush to the outside. A shutter is available as an accessory which can be easily fitted within the unit, see below.

On new building work the installation and wiring of the wall liner can be completed prior to the final installation of the unit and controller. Fully shrouded connectors on the fascia automatically connect the wiring to the motor when fitted to the wall liner.

back to top

 hspace=

Motor

The motor is purpose-designed. Suitable for running at any angle. Quiet running, enclosed, sealed for life ball bearings.

Supply voltage: 220-240V/1/50Hz.

Suitable for operation in ambient temperatures from -40°C to +40°C.

Fitted with Standard Thermal Overload Protection (S.T.O.P.).

back to top

 hspace=

Shutter

Type SD/R. This extract/intake shutter fits inside the Vent-Axia unit and closes against unwanted backdraughts. It can be fitted at the same time as the unit or at a later date if required. Airflow operated for extract use, cord operated lock for intake use.

back to top

 hspace=

Controller

The Ecotronic 130 Controller is recommended for use with this model to provide full function control of the fan plus the option of sensor mode using a selection of electromechanical switches to provide automatic switching of the fan.

Alternatively, single speed extract is achieved using a normal On/Off switch.

back to top

 hspace=

Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools. The fascia, motor impeller assembly unplugs from the wall sleeve. The external weather louvre is removed into the room for cleaning. All plastic components can be washed.

back to top

 hspace=

Sensors

Ambient Response Humidity Sensor
Self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature.Night time RH increment setback feature.

Air quality sensor
Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas.

Ecotronic Humidity Sensor
The Ecotronic Humidity Sensor is an adjustable set point, solid state controller. A pullcord provides manual override, indicated by lamp. Adjustable from 65% to 90%RH. Ecotronic includes a relay and can be used with T-Series controller sensor mode.

back to top

 hspace=

Dimensions (mm)

Wall model dimensions Wall model dimensions

 Impeller dia. 150mm 190mm 230mm 300mm
 A 279 279 279 279
 B 203 279 279 356
 C 279 362 362 448
 Fixing hole Square 235 311 311 400
 Weight 4.1kg 5.7kg 6.7kg 10.1kg

back to top

 hspace=

Technical Data


 Unit size 6 7 9 12
 Type S6/WL S7/WL S9/WL S12/WL
 Stock Ref. No. 13 15 10A 13 25 10A 13 35 10A 13 45 10A
 Amps @ 240V 0.16 0.16 0.24 0.36
 Extract Perf MAX m³/h 340 544 856 1767
 Watts MAX. 32 34 53 84
 dB(A) (med) @ 3m 39 35 43 46
 Shutter Type SD/R 23 17 10 23 27 10 23 37 10 23 47 10
 Range-
 master
RVS Surface W30 01 10 W30 01 10 W30 01 10 W30 01 10
Flush Fitting W30 01 10
+ 40 01 44
W30 01 10
+ 40 01 44
W30 01 10
+ 40 01 44
W30 01 10
+ 40 01 44
 Time Switch Type TTC W36 13 10 W36 13 10 W36 13 10 W36 13 10
 Multi-unit Type MUC W36 23 10 W36 23 10 W36 23 10 W36 23 10

back to top

 hspace=

Typical Specification

Supply and install a Standard Range Wall fan as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX Telephone: 01293 526062.

The fan should have a rigid wall liner for maximum wall thickness of 279mm. The unit should have fixed electrical connections within the liner for a first fix in a new build situation.

The plate should have the facility to be fixed on the liner making the electrical connection complete.

The fan should have the option of a backdraught shutter.

The fan should be fully reversible and be able to be controlled by using variable speed controllers or by humidity, air quality or TimeSwitches.

The unit should meet with Document F of the Building Regulations. DEMKO Approved.

The motor should be suitable for mounting at any angle and suitable for operation in ambient temperatures from -40°C to +40°C and should be fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).

back to top

Vent-Axia
Information:
»Description
»Dimensions
»Typical Specification

Downloads:
PDF availableCatalogue Pages
PDF availableO&M Instructions

At a Glance:
Extract/intake models in 4 sizes:
Size 6, 7, 9 and 12.
Ivory fascia, wall sleeve and black external weather louvre.
Manufactured in weather-resistant polymeric materials.
Optional shutter available.
For the best performance from your fan use an Ecotronic 130 controller.
DEMKO Approved.

FAQs Answered:
Fixed wall liner for cavity external walls.
Built-in flap shutter available.
Infinitely variable speed controller.
Standard Range controllers require 4 core wire.

  [ HOME | TOP ]  
 © Copyright 2007, Vent-Axia Ltd