Vent-Axia - Heating, Ventilation and Air Conditioning
HomeAbout UsWhat's NewOur ProductsFan SelectorBuying ProductsKnowledge CentreContact Us

 Product Search:
 

 
Our Products

  Vent-Axia Lo-Carbon Ventilation Range
 
 Domestic Ventilation Product Range
 Commercial Ventilation Product Range
 Vent-Axia Industrial Product Range
 Roof Units Product Range
 Sentinel Demand Ventilation
 Sentinel Totus Demand Energy Recovery Ventilation
 Heat Recovery & Mechanical Extract Systems
 Commercial Air Curtains
 Smoke Fans Range Guide
 Vent-Axia Air Handling
 Vent-Axia Cooling Range
 Vent-Axia Heating Range
 Hygiene Product Range
 Sensors, Controllers & Accessories

Online Shopping

Catalogue Request

LinX Contractor Range

 Route: Our Products \ Commercial Ventilation Product Range \ LoWatt T-Series Roof Models

Vent-Axia LoWatt T-Series Roof Model
suitable for commercial applicationssuitable for health & leisure facilitiesideal for use in ducted systems


 hspace=

Description

Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the LoWatt T-Series roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.

Why choose LoWatt?

back to top

 hspace=

Shutter

With energy saving in mind LoWatt T-Series models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It will operate on both intake and extract and at any angle of mounting.

The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection.

When the ventilating unit is used with a LoWatt T-Series Controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window.

back to top

 hspace=

Flat roof

LoWatt T-Series flat roof installation LoWatt T-Series roof models may be installed through solid roofs using a roof plate assembly and, if required, an eggcrate grille or louvred grille in the ceiling below. Alternatively, if ventilation is from a suspended ceiling, single spigots and flexible ducting may be used to connect the unit and extract grille.


 hspace=

Corrugated roof

LoWatt T-Series roof models are suitable for fixing through corrugated sloped and vertical cladding using a suitable soaker flange. The soaker flange consists of a replacement sheet with a flat section to carry the unit. A suitable sealing compound should be used between the plate and the exterior unit seal.

 hspace=

Pitched roof

LoWatt T-Series pitched roof installation LoWatt T-Series roof models may be installed in fixing plates with zinc or lead weathering apron (provided by others), fitted directly to a tiled or slated roof to provide a water-tight installation. A suitable sealing compound should be used between the weathering apron and the exterior unit seal.


 hspace=

NEW LoWatt T-Series Controller

LoWatt Controller LoWatt T-Series Controllers are available in both Wired and Wire-less FM versions. The three speed push button surface mounted controllers provide intake/extract and shutter only options and auto mode position for use with external sensors.

Wired versions are connected to the fan using a plug-in Safety Extra Low Voltage 2-core signal cable supplied (10m), allowing simple and safe installation. Alternatively, the Wire-less FM controller offers full control without the need for any wiring, ideal for premises where installations need to be carried out with minimum disruption or where surface wiring can be classed as unsightly or obtrusive.

back to top

 hspace=

Sensors

Can be used in conjunction with a LoWatt T-Series Controller

Ambient Response Humidity Sensor - Self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature. Night time RH increment setback feature

Ecotronic Humidity Sensor - Adjustable set point, solid state controller. Pullcord provides manual override. Adjustable from 65% to 90%RH.

Air Quality Sensor - Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas

back to top

 hspace=

Performance

LoWatt T-Series Window model performance

 Unit Size LoWatt TX9RF
Wireless
LoWatt TX9RF
 Stock Ref. No. 45 61 72 45 61 68
 Amps @ 240V 0.34 0.34
 Extract
 Performance
 m³/h
Low 313 313
Med 526 526
High 693 693
 Watts (high) 29 29
 dB(A) (med) @ 3m 40 40

 Unit Size LoWatt TX12RF
Wireless
LoWatt TX12RF
 Stock Ref. No. 45 61 80 45 61 76
 Amps @ 240V 0.69 0.69
 Extract
 Performance
 m³/h
Low 518 518
Med 1017 1017
High 1194 1194
 Watts (high) 67 67
 dB(A) (med) @ 3m 48 48

Recommended controller:
Wire-less Controller Stock Ref. No. 45 58 74
Wired Stock Ref. No. 45 58 73


back to top

 hspace=

Dimensions (mm)


LoWatt T-Series Roof model dimensions

 Size A B C D E F Fixing Hole Weight
kg
 230mm 136 150 304 302 54 400 260 6.22
 300mm 171 177 381 378 54 500 337 9.28

back to top

Vent-Axia Lo-Carbon™
Vent-Axia Lo-Carbon™ - 109kg carbon saving
Information:
»Description
»Controllers
»Performance
»Dimensions

Downloads:
PDF availableCatalogue Pages

At a Glance:
Extract/intake model in 2 sizes: Size 9 and 12
Patented electronic shutter system ensures quiet trouble free operation
Designed to comply with International safety standards
Up to 80% energy saving

FAQs Answered:
Wired or Wire-less fan models available
T-Series controllers and sensors save energy by only switching the units On when you want them to, either manually or automatically
Long life LoWatt motor lasts twice as long as other conventional motors
5 year guarantee
* Savings are based on an annual usage of 12 hours a day