Sentinel Kinetic B
High efficiency, compact, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit.
With Summer Bypass.
| No: 438222 150 in stock |
This product is part of the Lo-Carbon Sentinel Kinetic range:
Using the Vent-Axia Lo-Carbon range can reduce electrical consumption, thus reducing the overall carbon footprint.
When using heat recovery ventilation, the heating system requirement is reduced thus potentially saving another 500kg of carbon per annum.
The Sentinel Kinetic incorporates:
A wholehouse heat recovery system with up to 92% energy
efficiency.
Range includes; non-Summer Bypass and Summer Bypass, Cooker Hood with white finish, Cooker Hood with brushed aluminium finish.
Features and Benefits
• Manufactured in the UK
• Building Regulations Part F compliant
• SAP Appendix Q Eligible
• Energy savings trust best practice compliant
• Up to 92% heat recovery whilst controlling condensation
• Optional, programmable Summer bypass
• Cooker Hood version available
• Left or right hand installation (V, B and BH models)
• Horizontal and/or vertical duct outlets
• Integrated digital controller for simple and accurate commissioning
• Light weight for easy installation
• External condensate connection
• Plug and play controls; Humidistat, Vent-Wise, Wireless remote
• BMS connectivity
• LS inputs. (Light switch)
• Volt-free inputs
• Self diagnosis for simplified fault finding
• Multiple switching options: Light switch, PIR, Humidistat etc
• Adjustable delay on/delay off timer
• Easy access G3 filters
• Compact size - fits in a 600mm x 300mm kitchen cupboard (V and B models)
An easily accessible heat recovery cube protected by
two removable EU3 filters. Two Lo-Carbon Energy Saving EC DC
fans ensure long life (typically over double the life of AC motors)
and lowest possible energy use. Fully insulated construction with
built in condensation drain. Fitted with 125mm spigots.
Specifically designed for new build homes with a high level of insulation.
Lo-Carbon Sentinel Kinetic meets the latest requirements of the Building Regulations Document F 2010 for wholehouse system ventilation: System 4. Continuous mechanical supply and extract with heat recovery.
Range Product Specification
The Lo-Carbon Sentinel Kinetic models have 2 fully adjustable speeds and a purge setting - maximum. On the front of the unit is a digital controller that can be used to pre-set the speeds to any required air-flow within the performance range.
The Sentinel Kinetic models can be mounted vertically in a roof space, and are suitable for wall mounting or within a kitchen cupboard. When mounted in an unheated area ducting should be insulated. Ducting can be attached to the unit horizonally, vertically or both. Minimum internal depth of kitchen cupboard:
V, B and BH models 290mm.
CW models 300mm.
Left or right hand installation. The unit is supplied with duct spigots to outside on the right hand side. These can be reversed onsite by simply removing the control panel,
rotating the unit 180 degrees and re-attaching the control panel.
Horizontal and vertical spigots: The combination of spigot options allows installation in confined locations. If vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied.
Condensate drain can be taken out through the back, bottom or front of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can
be completed after installation.

Typical Range Specifications
Supply and install a Sentinel Kinetic system Wholehouse heat recovery unit as manufactured by:
Vent-Axia Clean Air Systems
Fleming Way
Crawley
West Sussex
RH10 9YX
| Performance: | m³/h | l/s |
| Max ventilation rate | 245 at 100Pa | 68 |
| N° speed settings | 3 (variable between 10% and 100%) |
Efficiency: The unit should retain up to 92% of the temperature differential of out going air.
Heat exchanger: should be of a multi plate counter-flow type constructed out of PETG with ultra sonic welded joints.
Motor: should be a Lowatt Energy Saving DC with ball bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with an electronic thermal overload protective device.
Fan: The fan impeller should be of a forward curved centrifugal type, dynamically balanced.
Controls: The unit should contain an integral driver circuit that provides the unit with a constant airflow volume feature. With provision to connect a remote manual 3 speeds.
Ducting spigots: The unit should provide 125mm ø x 50mm long spigots for all duct connections with vertical and horizontal locations. (Can be converted to flat ducting).
Filter: should be synthetic material tested to minimum of EU3.
Condensation: The outlet provided should offer front, rear and bottom connections external to the unit.
Construction: The unit outer case should be constructed of white ABS. The heat exchanger access doors should give tool-free access to the filters.
Mounting: Vertical, floor or wall mounted, or within kitchen cupboard.
Mains electrical supply: 230VAC 50Hz.
Complies to the following approvals/directives: CE, LVD, EMC. SAP Appendix Q eligible.
| Sentinel Kinetic V High efficiency, compact, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit.
| |||||
| Sentinel Kinetic B High efficiency, compact, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit. With Summer Bypass.
| |||||
| Sentinel Kinetic BH High efficiency, compact, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit. With Summer Bypass and Integral Built-In Humidistat.
| |||||
| Sentinel Kinetic CW L High efficiency, compact, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit. Features Summer Bypass and Telescopic Cooker Hood with white painted fascia. Hood incorporates fire damper and thermal overheat trip. LEFT hand model (with ducts to atmosphere on the left of the unit).
| |||||
| Sentinel Kinetic CS L High efficiency, compact, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit. Features Summer Bypass and Telescopic Cooker Hood with brushed aluminium fascia. Hood incorporates fire damper and thermal overheat trip. LEFT hand model (with ducts to atmosphere on the left of the unit).
| |||||
![]() | Sentinel Kinetic CW R High efficiency, compact, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit. Features Summer Bypass and Telescopic Cooker Hood with white painted fascia. Hood incorporates fire damper and thermal overheat trip. RIGHT hand model (with ducts to atmosphere on the right of the unit).
| ||||
![]() | Sentinel Kinetic CS R High efficiency, compact, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit. Features Summer Bypass and Telescopic Cooker Hood with brushed aluminium fascia. Hood incorporates fire damper and thermal overheat trip. RIGHT hand model (with ducts to atmosphere on the right of the unit).
|
![]() | Wireless enable kit The Wireless enable kit allows the Kinetic to be set to boost or purge from a remote wireless switch. One switch is supplied with the kit. Up to three additional switches may be linked to the wireless receiver.
| ||||
![]() | Wireless Transmitter Controller • Additional controller for 441865 and 439352 • A maximum of 4 controllers can be used per system • Can be connected to other accessories (eg Humidistat) to send a boost signal wirelessly
| ||||
![]() | Kinetic Integral Humidistat The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet-room. • Simple Plug-n-Play installation • Eliminates the need for additional controllers or sensors • Reacts to any rapid increases in relative humidity or relative humidity above 60% • Future proof – can be fitted after installation
| ||||
| Sentinel Kinetic Wired Remote Controller The Kinetic Wired Remote Controller duplicates all the functions of the on-board controller allowing the unit to be commissioned, controlled and monitored remotely. The controller is supplied with 15 metres of four core cable fitted with an RJ11 plug for fitting to the Kinetic control pcb.
| |||||
![]() | Kinetic Vent Wise Controller The award wining Vent Wise controller has been designed to fully automate a ventilation system. The unit can be used to switch the unit between trickle and boost speed. The controller saves energy by only switching when cooking is taking place or condensation is being generated. The current sensor detects when the power supply to an oven or hob is switched on. The temperature sensor detects the rise in temperature in the hot feed to a bath or shower. A combination of up to three sensors may be used with one controller
| ||||
![]() | Ventwise Current Sensor 4m Current sensor for use with Ventwise Controller. 4 metre lead length
| ||||
![]() | Ventwise Current Sensor 6m Current sensor for use with Ventwise Controller. 6 metre lead length
| ||||
![]() | Ventwise Current Sensor 12m Current sensor for use with Ventwise Controller. 12 metre lead length
| ||||
![]() | Ventwise Temperature Sensor 4m Temperature sensor for use with Ventwise Controller. 4 metre lead length
| ||||
![]() | Ventwise Temperature Sensor 6m Temperature sensor for use with Ventwise Controller. 6 metre lead length
| ||||
![]() | Ventwise Temperature Sensor 12m Temperature sensor for use with Ventwise Controller. 12 metre lead length
|
Downloads for the Lo-Carbon Sentinel Kinetic range
- 441879 A SENTINEL KINETIC WIRING DIAGRAM HUMIDISTAT REMOTE C H.pdf
- 441883 A SENTINEL KINETIC HUMIDISTAT BUILT IN C H.pdf
- 441088 A_SENTINEL KINETIC WIRED VIA A LIGHT SWITCHHUMIDISTAT BUILT IN COOKER HOOD.pdf
- 441087 A_SENTINEL KINETIC WIRED VIA A LIGHT SWITCHHUMIDISTAT REMOTE COOKER HOOD.pdf
- 442312 A Trickle Boost Switch.pdf
- 442311 A Two Trickle Boost Switches.pdf
- Cooker Hood Wall Template Left Hand.pdf
- Cooker Hood Wall Template Right Hand.pdf
- Kinetic Octave Band Sound Data.pdf
- 443766B_KINETIC SWITCHED TO BOOST BY 2 LIGHTING CIRCUITS OR A TRICKLE BOOST SWITCH.pdf
- FW&OM Instructions - Cooker Hood Suplementary
- Catalogue Pages Sentinel Kinetic.pdf
- Catalogue Pages Sentinel kinetic cookerhood.pdf
- F&W Instructions
- User Manual